S e n d d o c u m e n t c o m m e n t s t o n e x u s 7 k - f e e d b a c k - d o c @ c i s c o . c o m
2-630
Cisco NX-OS System Messages Reference
OL-15994-03
Chapter 2 System Messages and Recovery Procedures
SVC Messages
Error Message
SVC-2-SVC_SYSLOG_PATH_FAILURE: System health detected SVC packet path
failure for [chars].
Explanation
The CSM has been brought down by the system health monitor. The system Health has
detected a failure in the packet path between the SVC interface on the CSM and the backplane. This
The system Health test is run periodically.
Recommended Action
Issue a no shutdown on the SVC interface to bring the node back online. If a
subsequent packet path failure occurs, the CSM module should be replaced.
Error Message
SVC-2-SVC_SYSLOG_URIFS_FAILURE: [chars] is unreachable for reason:
[chars]
Explanation
SVC interface modflash is not accessible. Modflash is the name of the file system local
to the SVC interface, and is typically used for coredumps and temporary file transfers.
Recommended Action
Please shutdown and bring up the SVC interface in question to regain access
to the modflash file system.
SVC-3
Error Message
SVC-3-NODE_ERR_MSG: (SVC [dec]/[dec]
SS_EID_EC_ER_ACTIVATE_CLUSTER_IP_FAILED ) Activate cluster IP failed [chars]
Explanation
The system is unable to activate the cluster IP for the config node. It will not be possible
to execute configuration commands.
Recommended Action
1. Shutting the interfaces of the node will force this node out of the cluster and
cause another node to become the config node, which should restore the ability to execute
configuration commands. 2. If the error persists, re-install the code on the node. The node will then
have to be removed and re-added back to the cluster. 3. Ensure that the software is at the latest level
on the cluster. If not, upgrade the cluster and if necessary repeat step 2 with the latest level of code.
4. If the error continues, ask IBM Product Support for assistance.
Error Message
SVC-3-NODE_ERR_MSG: (SVC [dec]/[dec] SS_EID_EC_ER_BATT_FAILURE )
Battery Failed [chars]
Explanation
The battery module on the Caching Services Module has failed. The nodes on the CSM
will have shutdown. Other log entries may accompany this error.
Recommended Action
Reload the Caching Services Module. If the error persists, replace the Caching
Services Module.