![Cisco AP775A - Nexus Converged Network Switch 5010 Скачать руководство пользователя страница 674](http://html.mh-extra.com/html/cisco/ap775a-nexus-converged-network-switch-5010/ap775a-nexus-converged-network-switch-5010_reference_67336674.webp)
S e n d d o c u m e n t c o m m e n t s t o n e x u s 7 k - f e e d b a c k - d o c @ c i s c o . c o m
2-636
Cisco NX-OS System Messages Reference
OL-15994-03
Chapter 2 System Messages and Recovery Procedures
SVC Messages
Error Message
SVC-3-NODE_ERR_MSG: (SVC [dec]/[dec] SS_EID_VL_ER_IO_TIMEOUT_OVERALL
) Timeout due to excessive processing time [chars]
Explanation
A managed disk has timed out. This error has been reported because a large number of
disk timeout conditions have been detected. The problem is probably caused by a failure of some
other component on the SAN.
Recommended Action
1. Repair problems on all disk controllers and switches on the same SAN as
this cluster. 2. If problems are found, mark this error as fixed. 3. If no switch or disk controller
failures can be found, take an error log dump and call your hardware support center.
Error Message
SVC-3-NODE_ERR_MSG: (SVC [dec]/[dec]
SS_EID_VL_ER_LOCAL_PORT_EXCLUDED ) Local FC port excluded [chars]
Explanation
A local fibre-channel port has been excluded.
Recommended Action
1. Repair the fibre-channel network fabric. 2. Check the status of the disk
controller. 3. If all disk controllers show good status, mark the error you have just repaired as fixed.
4. If the error persists and no other cause can be determined, replace the Caching Services Module.
Error Message
SVC-3-NODE_ERR_MSG: (SVC [dec]/[dec] SS_EID_VL_ER_LOGIN_EXCLUDED )
Login excluded [chars]
Explanation
Login has been excluded.
Recommended Action
1. In the sequence shown, exchange the FRUs for new FRUs: Fibre Channel
cable, switch to remote port. 2. Start a cluster discovery operation to recover the login. 3. Check the
status of the disk controller. If all disk controllers show a good status, mark the error you have just
repaired as fixed. 4. If the error persists and no other cause can be determined, replace the Caching
Services Module.
Error Message
SVC-3-NODE_ERR_MSG: (SVC [dec]/[dec]
SS_EID_VL_ER_LUN_RESOURCE_RAN_OUT ) Too many LUNs were presented to a node [chars]
Explanation
The configuration is not valid. Too many devices have been presented to the cluster or
node.
Recommended Action
1. Remove unwanted devices from the fibre-channel network fabric. 2. Start a
cluster discovery operation to find devices. 3. List all connected managed disks. Check that the
configuration is as expected. Mark the error you have just repaired as fixed.