Error Message
PMALLOC-6-MMAP_SIZE Format: MMAP size is: %d\n
Explanation
In PMALLOC lib, Memory map size.
Parameters: Memory Map size ...
Recommended Action
No action is required.
Error Message
PMALLOC-6-SBRK_FAILURE Format: sbrk failed in %s\n
Explanation
In PMALLOC lib, return vlaue from MORECORE failed.
Parameters: Function name ...
Recommended Action
No action is required.
PORT Messages
This section contains the PORT messages.
PORT-2
Error Message
PORT-2-IF_DOWN_ERROR_DISABLED: Interface [chars] is down (Error
disabled)
Explanation
The system has detected that the interface has has detected an error during the
configuration.
Recommended Action
Collect more information about the failed interface using the command 'show
port internal all interface [char]'. In most cases, you can recover using the following commands
'config terminal', 'interface [char]', 'shutdown', 'no shutdown' on the interface or remove and reinsert
the fiber optic cable.
PORT-3
Error Message
PORT-3-IF_SFP_ALARM: Interface [chars], [chars]
Explanation
There was an alarm on the transceiver module.
Recommended Action
Enter the show interface transceiver details command to obtain more