![Cisco AP775A - Nexus Converged Network Switch 5010 Скачать руководство пользователя страница 481](http://html.mh-extra.com/html/cisco/ap775a-nexus-converged-network-switch-5010/ap775a-nexus-converged-network-switch-5010_reference_67336481.webp)
S e n d d o c u m e n t c o m m e n t s t o n e x u s 7 k - f e e d b a c k - d o c @ c i s c o . c o m
2-443
Cisco NX-OS System Messages Reference
OL-15994-03
Chapter 2 System Messages and Recovery Procedures
PIM Messages
PIM Messages
This section contains the PIM messages.
PIM-2
Error Message
PIM-2-SHM_LOCK_CREAT Format: Failed to create shared memory lock: %s
Explanation
The system has failed to initialize.
Parameters: Error Name ...
Recommended Action
Use 'reload' command to reload the system. Be aware that this problem affects
all VDCs on the system.
Error Message
PIM-2-STARTUP_DEBUG Format: %s in %s
Explanation
The system has failed to initialize.
Parameters: Error, Function Name ...
Recommended Action
No action is required.
PIM-3
Error Message
PIM-3-ADD_ROUTE Format: Couldn't add PIM route %s in %s
Explanation
PIM failed to update the local route-table entry.
Parameters: Addresses, Function Name ...
Recommended Action
No action is required.
Error Message
PIM-3-API_CLOSE Format: Couldn't close %s API
Explanation
PIM failed to close API opened with the component.
Parameters: Component Name ...
Recommended Action
No action is required.
Error Message
PIM-3-API_FAILED Format: %s failed in %s
Explanation
PIM process failed in invoking an API.
Parameters: Function Name ...
Recommended Action
No action is required.