Chapter 2 System Messages and Recovery Procedures
PLATFORM Messages
Error Message
PLATFORM-2-PS_AC_IN_MISSING: Power supply [dec] present but all AC
inputs are not connected, ac-redundancy might be affected
Explanation
Power Supply is present but not at full capacity.
Recommended Action
No action is required.
Error Message
PLATFORM-2-PS_CAP_CHG: AC Input insertion/removal detected for power
supply [dec]. This might results in change of total power available.
Explanation
AC input cable has been plugged in/out or AC input power has been restoreddd/lost.
Recommended Action
Enter a 'show environment power' and 'the show platform internal command
rmationcommandrmationcommand' to collect more information. Refer to power supply document
on increasing decreasing power supply capacity, configuring power supplies, etc.
Error Message
PLATFORM-2-PS_CAPACITY_CHANGE: Power supply PS[dec] changed its
capacity. possibly due to power cable removal/insertion (Serial number [chars])
Explanation
Detected power supply capacity change.
Recommended Action
Refer to power supply document on increasing decreasing power supply
capacity, configuring power supplies, etc. Enter 'show environment power' and 'the show platform
internal command rmationcommandrmationcommand' to collect more information.
Error Message
PLATFORM-2-PS_CAPACITY_DIFFER: Detected power supplies with differing
capacity. It is recommended to have same capacity for both powersupplies otherwise
it may cause service disruptions
Explanation
Detected a power supply that has differing capacity than the other power supply.
Recommended Action
Refer to power supply document on increasing decreasing power supply
capacity, configuring power supplies, etc. Enter 'show environment power' and 'the show platform
internal command rmationcommandrmationcommand' to collect more information.
Error Message
PLATFORM-2-PS_DETECT: Power supply [dec] detected but shutdown
(Serial number [chars])
Explanation
Power Supply is detected but shutdown.
Recommended Action
Enter a 'show environment power' and 'the show platform internal command
rmationcommandrmationcommand' to collect more information.
Error Message
PLATFORM-2-PS_FAIL: Power supply [dec] failed or shut down (Serial
number [chars])
Explanation
Power Supply has failed or has been shutdown.
Recommended Action
Enter a 'show environment power' and 'the show platform internal command
rmationcommandrmationcommand' to collect more information. Refer to power supply document
on increasing decreasing power supply capacity, configuring power supplies, etc.