Chapter 2 System Messages and Recovery Procedures
FSPF Messages
Error Message
FSPF-6-DELETE_LSR: LSR deleted for domain [dec]
Explanation
The LSR for domain [dec] is deleted from the database.
Recommended Action
No action is required.
Error Message
FSPF-6-INTF_OPER_DOWN: Down on interface [chars]
Explanation
FSPF has become operationally down on interface [chars].
Recommended Action
No action is required.
Error Message
FSPF-6-INTF_OPER_UP: Up on interface [chars]
Explanation
FSPF has become operational on interface [chars].
Recommended Action
No action is required.
Error Message
FSPF-6-MAX_AGE: LSR [dec] reached Maxage
Explanation
The LSR for domain [dec] reached the maximum age and will be deleted from all the
connected switches .
Recommended Action
No action is required.
Error Message
FSPF-6-ROLLOVER: Rolling over the incarnation number of Local LSR
Explanation
The incarnation number of local LSR reached the maximum value and is rolling over.
Recommended Action
No action is required.
Error Message
FSPF-6-SELF_ORIGINATED: Received local LSR with higher incarnation
number
Explanation
A LSR for the local domain was received with incarnation number higher than the one
in database. This situation should only occur initially on a topology change. If this situation persists
the domain assignment of switches may not be unique.
Recommended Action
If this message is received continuously check if domain assignment is unique
in the fabric.
Error Message
FSPF-6-STATE_CREATED: Internal state created [chars]
Explanation
FSPF has created its internal state stateless/stateful [chars].
Recommended Action
No action is required.