S e n d d o c u m e n t c o m m e n t s t o n e x u s 7 k - f e e d b a c k - d o c @ c i s c o . c o m
2-473
Cisco NX-OS System Messages Reference
OL-15994-03
Chapter 2 System Messages and Recovery Procedures
PLATFORM Messages
PLATFORM Messages
This section contains the PLATFORM messages.
PLATFORM-0
Error Message
PLATFORM-0-CHASSIS_CLKSW_MODULE_RESET: Modules reset due to clock
switch
Explanation
Chassis clock source has switched and all Vegas line cards will be reset. The system
will automatically continue using redundant clock module.
Recommended Action
Refer to the platform document on clock modules.
Error Message
PLATFORM-0-CHASSIS_CLKSWITCH: Hardware clock switched to redundant
clock-[dec]
Explanation
Clock module on chassis deteted a failure and switched to redundant clock module.
Recommended Action
Enter the 'the show platform internal command
rmationcommandrmationcommand' to collect more information.
Error Message
PLATFORM-0-CHASSIS_CLKSWRESET: Switch reset due to clock switch
Explanation
Chassis clock source has failed and system will be reset. The system will automatically
start using redundant clock module.
Recommended Action
Refer to the platform document on clock modules.
Error Message
PLATFORM-0-FAIL_REMOVED: Fan module removed. Fan[dec] has been absent
for [dec] seconds
Explanation
Fan module is removed. This could lead to temperature alarms.
Recommended Action
Replace the fan module as soon as possible.
Error Message
PLATFORM-0-MOD_TEMPMAJALRM: [chars] reported Major temperature alarm.
Sensor=[dec] Temperature=[dec] MajThreshold=[dec]
Explanation
Module in slot [decimal digit] exceeded major temperature threshold.
Recommended Action
Enter a 'show env temperature' to collect more information.