![Cisco AP775A - Nexus Converged Network Switch 5010 Скачать руководство пользователя страница 675](http://html.mh-extra.com/html/cisco/ap775a-nexus-converged-network-switch-5010/ap775a-nexus-converged-network-switch-5010_reference_67336675.webp)
S e n d d o c u m e n t c o m m e n t s t o n e x u s 7 k - f e e d b a c k - d o c @ c i s c o . c o m
2-637
Cisco NX-OS System Messages Reference
OL-15994-03
Chapter 2 System Messages and Recovery Procedures
SVC Messages
Error Message
SVC-3-NODE_ERR_MSG: (SVC [dec]/[dec]
SS_EID_VL_ER_MDISK_ACCESS_INVALID ) Access beyond end of disk, or Managed Disk
missing [chars]
Explanation
The error that is logged in the cluster error log indicates a software problem either in
the cluster, or in a disk enclosure or disk controller that is connected to the node.
Recommended Action
1. Ensure that the software is at the latest level on the cluster and on the disk
controllers. 2. Run a configuration dump and a logged data dump. Save the dump data. 3. Contact
the Cisco Technical Assistance Center (TAC) through the Cisco Support web site
http://www.cisco.com/tac. 4. Mark the error you have just repaired as fixed.
Error Message
SVC-3-NODE_ERR_MSG: (SVC [dec]/[dec]
SS_EID_VL_ER_MDISK_DEVICE_PORT_EXCLUDED ) Remote Port excluded for a specific
Managed Disk and Node [chars]
Explanation
A remote fibre-channel port has been excluded.
Recommended Action
1. View the error log. Note the mdisk ID associated with the error code. 2.
Using the mdisk ID, determine the failing disk controller. 3. Refer to the service documentation for
the disk enclosure or disk controller and the fibre-channel network fabric to resolve the reported
problem. 4. Start a cluster discovery operation to recover the excluded fibre-channel port. 5. Include
the managed disk that you noted in step 1. 6. Check the status of the disk controller. If all disk
controllers show a good status, mark the error you have just repaired as fixed. 7. If all disk
controllers do not show a good status, contact the Cisco Technical Assistance Center (TAC) through
the Cisco Support web site http://www.cisco.com/tac. to resolve the problem with the disk
controller.
Error Message
SVC-3-NODE_ERR_MSG: (SVC [dec]/[dec] SS_EID_VL_ER_MDISK_EXCLUDED )
Managed Disk excluded due to excessive errors, or all device ports excluded [chars]
Explanation
A managed disk or managed disk controller port has been excluded because of
excessive errors or unusual behavior.
Recommended Action
1. Repair the enclosure or disk controller. 2. Check the managed disk status.
If any managed disks show a status of online, mark the error you have just repaired as fixed. If all
managed disks show a status of excluded, include the managed disks and then mark the error as
fixed.
Error Message
SVC-3-NODE_ERR_MSG: (SVC [dec]/[dec]
SS_EID_VL_ER_MDISK_INITIALISE_INVALID ) Invalid blocksize, capacity or LUN
identity has changed during Managed Disk initialisation [chars]
Explanation
Access beyond end of disk. The initialization of the managed disk has failed.
Recommended Action
1. Check the status of the managed disk and of the managed-disk group. 2.
Include the managed disk into the cluster. 3. Check the managed disk status. If all managed disks
show a status of online, mark the error you have just repaired as fixed. 4. If not all managed disks
show a status of online, check the status of the disk controller.