S e n d d o c u m e n t c o m m e n t s t o n e x u s 7 k - f e e d b a c k - d o c @ c i s c o . c o m
2-616
Cisco NX-OS System Messages Reference
OL-15994-03
Chapter 2 System Messages and Recovery Procedures
SPAN Messages
SPAN-2
Error Message
SPAN-2-MEM_FULL: Memory allocation failed
Explanation
Memory allocation failed.
Recommended Action
Contact the Cisco Technical Assistance Center (TAC) through the Cisco
Support web site http://www.cisco.com/tac.
SPAN-3
Error Message
SPAN-3-IPC_FAIL: IPC Error
Explanation
Internal IPC error.
Recommended Action
No action is required.
Error Message
SPAN-3-SYSINFO_TIMEOUT: Span timed out waiting for response from port
manager for sys info
Explanation
Span request for critical system information from port manager timed out. So, span on
the new active is exiting and system manager will restart Span.
Recommended Action
No action is required.
SPAN-5
Error Message
SPAN-5-ATL_VSAN_DEFAULT_ALL: Default to all VSANs for SPAN egress
session
Explanation
Generation 2 fabric switches support only one VSAN filter for egress SPAN session. If
no or more than one VSANs are specified, SPAN will default to use all VSANs for the egress SPAN
session.
Recommended Action
No action is required.
Error Message
SPAN-5-SPAN_CFG_REJECT_SRC_VSAN_FILTER_NOT_SUPPORTED: Source
interface [[chars]] in dir [[chars]] removed from session [[dec]].
Explanation
Interface level VSAN filters are not supported.
Recommended Action
No action is required.