Cisco NX-OS System Messages Reference
OL-15994-03
Chapter 2 System Messages and Recovery Procedures
SVC Messages
SVC-6
Error Message
SVC-6-NODE_INFO_MSG: (SVC [dec]/[dec] SS_EID_CA_EV_ALL_DATA_UNPINNED
) All data now unpinned [chars]
Explanation
All the customer data in the IO group is now unpinned.
Recommended Action
Contact the Cisco Technical Assistance Center (TAC) through the Cisco
Support web site http://www.cisco.com/tac.
Error Message
SVC-6-NODE_INFO_MSG: (SVC [dec]/[dec]
SS_EID_CA_EV_HWS_TO_ASYNCHRONOUS ) Pinned data reduced; cache can operate normally
[chars]
Explanation
Enough customer data has been unpinned that the cache is no longer required to operate
in write through mode because of the pinned data. (Note that the cache may still operate in write
through mode for other reasons.).
Recommended Action
Contact the Cisco Technical Assistance Center (TAC) through the Cisco
Support web site http://www.cisco.com/tac.
Error Message
SVC-6-NODE_INFO_MSG: (SVC [dec]/[dec] SS_EID_EC_ER_BATT_OK ) Battery
recharged [chars]
Explanation
Battery capacity has been restoredddd to above threshold. The node will now come
online.
Recommended Action
Contact the Cisco Technical Assistance Center (TAC) through the Cisco
Support web site http://www.cisco.com/tac.
Error Message
SVC-6-NODE_INFO_MSG: (SVC [dec]/[dec] SS_EID_EC_ER_BATT_POWER_DOWN )
Poweroff or power failure detected [chars]
Explanation
The process has received a poweroff or power failure indication. The node is shutting
down.
Recommended Action
Restore power. If power was not removed and this occurs: 1. Reload the node.
2. If the error persists, re-install the code on the line card. The node(s) will then have to be removed
and re-added back to the cluster. 3. If the error persists, replace the Caching Services Module.
Error Message
SVC-6-NODE_INFO_MSG: (SVC [dec]/[dec] SS_EID_EC_ER_PWR_BUTTON ) Power
withdrawn [chars]
Explanation
Node software was notified that AC power was being shut off or the Caching Services
Module was being reset.
Recommended Action
Contact the Cisco Technical Assistance Center (TAC) through the Cisco
Support web site http://www.cisco.com/tac.