S e n d d o c u m e n t c o m m e n t s t o n e x u s 7 k - f e e d b a c k - d o c @ c i s c o . c o m
2-644
Cisco NX-OS System Messages Reference
OL-15994-03
Chapter 2 System Messages and Recovery Procedures
SVC Messages
Error Message
SVC-4-NODE_WARNING_MSG: (SVC [dec]/[dec] SS_EID_EC_ER_EXECVE_FAILED
) Internal error - program launch [chars]
Explanation
The process was unable to launch the IO program. Node was rebooted due to this error.
Recommended Action
If this error is repeated continously, 1. Re-install the code on the node. The
node will then have to be removed and re-added back to the cluster. 2. Ensure that the software is at
the latest level on the cluster. If not, upgrade the cluster and if necessary repeat step 1 with the latest
level of code. 3. If the error continues, ask IBM Product Support for assistance.
Error Message
SVC-4-NODE_WARNING_MSG: (SVC [dec]/[dec] SS_EID_EC_ER_FORK_FAILED )
Internal error - fork failed [chars]
Explanation
The process was unable to launch the IO program. Node was rebooted due to this error.
Recommended Action
If this error is repeated continously, 1. Re-install the code on the node. The
node will then have to be removed and re-added back to the cluster. 2. Ensure that the software is at
the latest level on the cluster. If not, upgrade the cluster and if necessary repeat step 1 with the latest
level of code. 3. If the error continues, ask IBM Product Support for assistance.
Error Message
SVC-4-NODE_WARNING_MSG: (SVC [dec]/[dec]
SS_EID_EC_ER_INTERNAL_EXIT_LOGIC_ERR ) Internal error - bad exit code [chars]
Explanation
Node was warmstarted due to internal logic error.
Recommended Action
1. Ensure that the software is at the latest level on the cluster. 2. Contact the
Cisco Technical Assistance Center (TAC) through the Cisco Support web site
http://www.cisco.com/tac.
Error Message
SVC-4-NODE_WARNING_MSG: (SVC [dec]/[dec]
SS_EID_EC_ER_INTERNAL_UNKNOWN_EXEC_MODE ) Internal error - run mode [chars]
Explanation
Node was rebooted due to internal logic error.
Recommended Action
1. Ensure that the software is at the latest level on the cluster. 2. Contact the
Cisco Technical Assistance Center (TAC) through the Cisco Support web site
http://www.cisco.com/tac.
Error Message
SVC-4-NODE_WARNING_MSG: (SVC [dec]/[dec]
SS_EID_EC_ER_IOP_EXITED_DUE_TO_SIGNAL ) Internal error - signal caused exit
[chars]
Explanation
The IO process exited because of a signal which was not caught. Node was warmstarted
due to this error.
Recommended Action
1. Ensure that the software is at the latest level on the cluster. 2. Contact the
Cisco Technical Assistance Center (TAC) through the Cisco Support web site
http://www.cisco.com/tac.