S e n d d o c u m e n t c o m m e n t s t o n e x u s 7 k - f e e d b a c k - d o c @ c i s c o . c o m
2-632
Cisco NX-OS System Messages Reference
OL-15994-03
Chapter 2 System Messages and Recovery Procedures
SVC Messages
Error Message
SVC-3-NODE_ERR_MSG: (SVC [dec]/[dec]
SS_EID_EC_ER_SET_BATT_THRESHOLD_FAILED ) Set battery threshold failed [chars]
Explanation
The process was unable to set the battery threshold. Possibly due to fatal
communication failures with the power management module in the line card or the power
management module has crashed. Node was rebooted due to this error.
Recommended Action
If this error is repeated continously, 1. Re-install the code on the line card. The
node(s) will then have to be removed and re-added back to the cluster. 2. Ensure that the software is
at the latest level on the cluster. If not, upgrade the cluster and if necessary repeat step 1 with the
latest level of code. 3. If the error persists, replace the Caching Services Module.
Error Message
SVC-3-NODE_ERR_MSG: (SVC [dec]/[dec]
SS_EID_IC_EV_NODE_DISENFRANCHISED ) Node missing [chars]
Explanation
A node is missing from the cluster.
Recommended Action
1. If it is not obvious which node in the cluster has failed, check the status of
the nodes and find the node with a status of offline. 2. Repair the failing node. 3. When the repair
has been completed, this error will automatically be marked as fixed. 4. Check the node status. If all
the nodes in the cluster are now online, but the error in the log has not been marked as fixed,
manually mark the error as fixed.
Error Message
SVC-3-NODE_ERR_MSG: (SVC [dec]/[dec]
SS_EID_PL_ER_CLUSTER_PATH_FAILURE ) Cluster path failure [chars]
Explanation
A cluster path has failed. The node is unable communicate with all the other nodes in
the cluster.
Recommended Action
1. Repair the fibre-channel network fabric. 2. Check the status of the node port.
If the status of the port shows as online, mark the error you have just repaired as fixed.
Error Message
SVC-3-NODE_ERR_MSG: (SVC [dec]/[dec] SS_EID_PL_ER_CPU_QUANTITY )
Processor change detected [chars]
Explanation
The Caching Services Module is failing.
Recommended Action
1. Replace the Caching Services Module. 2. Check node status. If all nodes
show a status of online, mark the error you have just repaired as fixed.
Error Message
SVC-3-NODE_ERR_MSG: (SVC [dec]/[dec] SS_EID_PL_ER_DISK_FULL ) Node
hard disk full [chars]
Explanation
The error that is logged in the cluster error log indicates a software problem in the
cluster.
Recommended Action
1. Ensure that the software is at the latest level on the cluster. 2. Delete files
from the /dumps directory. 3. Run a configuration dump and a logged data dump. Save the dump
data. 4. Contact the Cisco Technical Assistance Center (TAC) through the Cisco Support web site
http://www.cisco.com/tac. 5. Mark the error you have just repaired as fixed.