S e n d d o c u m e n t c o m m e n t s t o n e x u s 7 k - f e e d b a c k - d o c @ c i s c o . c o m
2-479
Cisco NX-OS System Messages Reference
OL-15994-03
Chapter 2 System Messages and Recovery Procedures
PLATFORM Messages
Error Message
PLATFORM-2-MOD_ALL_PWRDN_NOXBAR: All modules powered down due to
non-availability of xbar modules
Explanation
All modules in switch are powered down because all xbar modules are offline.
Recommended Action
Enter a 'show module', 'show platform internal all module [decimal digit]' and
'show module internal all module [decimal digit]' to collect more information if you suspect module
has been powered down due to errors.At leastone xbar module has to be for modules to function.
Error Message
PLATFORM-2-MOD_DETECT: Module [dec] detected (Serial number [chars])
Module-Type [chars] Model [chars]
Explanation
A new module in slot [decimal digit] is detected.
Recommended Action
No action is required.
Error Message
PLATFORM-2-MOD_PWRDENY: Module [dec] can not be powered up due to
insufficient power (Serial number [chars])
Explanation
Available power in power supplies is not sufficient to power up the module.
Recommended Action
You can verify available power and current usage using the command 'show
env power'. Refer to power supply document on how to increase power supply capacity.
Error Message
PLATFORM-2-MOD_PWRDN: Module [dec] powered down (Serial number
[chars])
Explanation
The module in slot [decimal digit] is powered down.
Recommended Action
Enter a 'show module', 'show platform internal all module [decimal digit]' and
'show module internal all module [decimal digit]' to collect more information if you suspect module
has been powered down due to errors.
Error Message
PLATFORM-2-MOD_PWRFAIL: Module [dec] failed to power up (Serial number
[chars])
Explanation
The module in slot [decimal digit] failed to power up.
Recommended Action
Enter a 'show platform internal all module [decimal digit]' and to collect more
information.
Error Message
PLATFORM-2-MOD_PWRFAIL_EJECTORS_OPEN: Both ejectors open, Module
[dec] will not be powered up (Serial number [chars])
Explanation
The module cannot be powered up because both ejectors are open.
Recommended Action
Enter a 'show platform internal all module [decimal digit]' and 'show module
internal all module [decimal digit]' 'show sprom xbar [dec] [dec]' to read module IDPROM contents
to collect more information.