S e n d d o c u m e n t c o m m e n t s t o n e x u s 7 k - f e e d b a c k - d o c @ c i s c o . c o m
2-489
Cisco NX-OS System Messages Reference
OL-15994-03
Chapter 2 System Messages and Recovery Procedures
PLATFORM Messages
Error Message
PLATFORM-2-PS_REMOVE: Power supply [dec] removed (Serial number
[chars])
Explanation
Power Supply is removed.
Recommended Action
No action is required.
Error Message
PLATFORM-2-PS_REMOVE_LAST: Unexpected removal of last power supply
[dec]. (Serial number [chars])
Explanation
Unexpected removal of the only power supply in the system.
Recommended Action
Power supply unit may be faulty. Contact the Cisco Technical Assistance
Center (TAC) through the Cisco Support web site http://www.cisco.com/tac.
Error Message
PLATFORM-2-PS_UNKNOWN: Detected an unknown power supply [dec] for
CISCO Multilayer Switch (Serial number [chars])
Explanation
The system is unable to determine power supply type. Default power supply types will
be assumed.
Recommended Action
Refer to power supply document on increasing decreasing power supply
capacity, configuring power supplies, etc.
Error Message
PLATFORM-2-PS_UNSUPPORTED: Detected an unsupported power supply [dec]
[chars] for CISCO Multilayer Switch (Serial number [chars])
Explanation
This power supply is not supported for the Cisco Multilayer Switches.
Recommended Action
Refer to power supply document on increasing decreasing power supply
capacity, configuring power supplies, etc.
Error Message
PLATFORM-2-SYS_IDPROMBAD: Chassis IDPROM [dec] data invalid
Explanation
Chassis IDPROM [decimal digit] contains invalid data.
Recommended Action
Enter a 'show sprom module [decimal digit] 1' to read module IDPROM
contents and collect more information.
Error Message
PLATFORM-2-SYS_IDPROMBAD_RECOVER_FAIL: Chassis IDPROM [dec] data
re-initialization Un-successful. Data is invalid
Explanation
Chassis IDPROM [decimal digit] re-initialization was unsuccessful. Data is invalid.
Recommended Action
Enter a 'show sprom module [decimal digit] 1' to read module IDPROM
contents and collect more information.