20-10
FRX8000 3. 0 User G uide, Rev 02
Cumulative Statistics Parameters
Report to NMP
determines which ICP/INM/NMP will receive the file.
Time Interval
is the period over which statistics will accumulate. When the interval expires, the
totals will be sent to the ICP/INM/NMP, the timer will be reset, and accumulation will
begin again.
Cum. Stats. On/Off
determines whether or not statistics are being gathered.
Statistics File Creation
When statistics data is sent to an ICP/INM/NMP, it will be added to a file named
CSTAT.DAT. (If the file does not exist, it will be created; if it does exist, the data will
be appended to it.) Once the file size exceeds 1MByte, the file will be closed and saved
as CSTAT.DAT.BAK, and a new CSTAT.DAT will be created to hold new data. When
the “new” CSTAT.DAT reaches 1MByte, it will be saved as CSTAT.DAT.BAK, a new
CSTAT.DAT will be created, and so on.
The maximum file size for CSTAT.DAT can be changed, as described under
“
Changing the Cumulative Statistics File Size
” on page F-3.
Producing a Cumulative Statistics Report
As described in the previous section, cumulative statistics are sent to the INM/NMP/
ICP every “n” minutes. To produce a report listing each set of values of cumulative
statistics that have been sent over a specified period, press
[B]
at the Cumulative Sta-
tistics Menu (or
[F], [F], [B]
from the Main Menu). When prompted, enter:
●
Node ID
:
1–250
. (Default is the local node.)
●
LP number
:
0–7.
(Default is
0
.)
●
Port
:
0–63
. (Default is
0
.)
●
Display Option: d
to display,
p
to print, or
f
to write to a file.
●
From (YY-MM-DD-HH-MM)
, which specifies the time of the oldest report to the
ICP/INM/NMP that you want included in this report.
YY
= Year (
00–99
)
MM
= Month (
01–12)
DD
= Day (
01–31
)
HH
= Hour (
00–23
)
mm
= Minute (
00–59
)
●
To (YY-MM-DD-HH-MM)
, which specifies the time of the latest report to the ICP/
INM/NMP that you want included in this report.
Table 20-1 Cumulative Statistics Parameters
Parameter
Valid Values
Default Value
Report to NMP
1–250
local node
Time Interval
(min)
1–1440
1
Cum. Stats. O n/ Off
0
(off)
or 1
(on)
0
Содержание Netlink FRX8000
Страница 1: ...User Guide For Release 3 0 09 41 06 150 02 The Complete Networking Solution T M ...
Страница 2: ......
Страница 14: ......
Страница 15: ...Section I Getting Started ...
Страница 16: ......
Страница 25: ...Section II Configuration ...
Страница 26: ......
Страница 40: ......
Страница 60: ......
Страница 80: ......
Страница 106: ...7 26 FRX8000 3 0 User Guide Rev 02 ...
Страница 148: ...9 30 FRX8000 3 0 User Guide Rev 02 ...
Страница 251: ...Section III Operation ...
Страница 252: ......
Страница 392: ......
Страница 397: ...Section IV Appendices ...
Страница 398: ......
Страница 410: ......
Страница 444: ......
Страница 448: ......