If the system hangs on a progress code, follow the suggested actions in the order in which they are listed
in the Action column until the problem is solved. If an action solves the problem, you can stop performing
there maining actions.
•
See
Chapter 3
, “
Parts listing
,” on page
197
to determine which components are CRUs and which
components are FRUs.
Progress code
Description
Action
C103A3xx
Hypervisor data structures are being
transferred to system storage
1. Go to “
Checkout procedure
” on page
148
.
2. Replace the system-board and chassis assembly,
as described in “
Replacing the Tier 2 system-
board and chassis assembly
” on page
229
.
C103A400
Special purpose registers are loaded
and instructions are started on the
system processors
1. Go to “
Checkout procedure
” on page
148
.
2. Replace the system-board and chassis assembly,
as described in “
Replacing the Tier 2 system-
board and chassis assembly
” on page
229
.
C103A401
Instructions have been started on the
system processors
1. Go to “
Checkout procedure
” on page
148
.
2. Replace the system-board and chassis assembly,
as described in “
Replacing the Tier 2 system-
board and chassis assembly
” on page
229
.
C116C2xx
System power interface is listening for
power fault events from SPCN. The last
byte (xx) will increment up from 00 to
1F every second while it waits.
1. Go to “
Checkout procedure
” on page
148
.
2. Replace the system-board and chassis assembly,
as described in “
Replacing the Tier 2 system-
board and chassis assembly
” on page
229
.
C162E4xyy
VPD is being collected; yy indicates the
type of device from which VPD is being
collected
1. Go to “
Checkout procedure
” on page
148
.
2. Replace the system-board and chassis assembly,
as described in “
Replacing the Tier 2 system-
board and chassis assembly
” on page
229
.
C1645300
Starting a data synchronization
operation between the primary service
processor and the secondary service
processor.
1. Go to “
Checkout procedure
” on page
148
.
2. Replace the system-board and chassis assembly,
as described in “
Replacing the Tier 2 system-
board and chassis assembly
” on page
229
.
Содержание Escala BL460
Страница 1: ...Escala BL460 Problem Determination and Service Guide ESCALA Blade REFERENCE 86 A7 81FB 00...
Страница 2: ......
Страница 10: ......
Страница 11: ...Preface vii Safety...
Страница 13: ...Preface ix...
Страница 14: ...x Escala BL460 Problem Determination and Service Guide...
Страница 15: ...Preface xi...
Страница 16: ...xii Escala BL460 Problem Determination and Service Guide...
Страница 17: ...Preface xiii...
Страница 19: ...Preface xv Guidelines for servicing electrical equipment...
Страница 20: ......
Страница 26: ...6 Escala BL460 Problem Determination and Service Guide Figure 1 1 DIMM connectors...
Страница 33: ...Chapter 1 Introduction 13 Figure 1 4 shows individual DIMM connectors Figure 1 4 DIMM connectors...
Страница 220: ...200 Escala BL460 Problem Determination and Service Guide...
Страница 260: ...240 Escala BL460 Problem Determination and Service Guide...
Страница 265: ......
Страница 266: ...BULL CEDOC 357 AVENUE PATTON B P 20845 49008 ANGERS CEDEX 01 FRANCE REFERENCE 86 A7 81FB 00...