186
Escala BL460 -
Problem Determination and Service Guide
2.13
Recovering the system firmware
The system firmware is contained in separate temporary and permanent images in the flash
memory of the blade server. These images are referred to as TEMP and PERM, respectively.
The blade server normally starts from the TEMP image, and uses the PERM image as a
backup. If the TEMP image becomes damaged, such as from a power failure during a
firmware update, you can recover the TEMP image from the PERM image.
If your system hangs, access the management module and select Blade Tasks
→
Configuration
→
Boot Mode to show the Escala BL460 blade server in the list of blade
servers in the Bull Blade Chassis - Enterprise. Click the appropriate blade server and select
Permanent to force the system to start from the PERM image.
See the documentation for the management module to learn more.
2.13.1
Starting the PERM image
You can force the blade server to start the PERM (permanent) image.
To force the blade server to start the PERM (permanent) image, complete the following
procedure.
1.
Access the Chassis Management Module menus.
2.
Click Blade Tasks
→
Configuration
→
Boot Mode.
3.
Click the appropriate Escala BL460 blade server in the list of blade servers in the Bull
Blade Chassis - Enterprise.
4.
Select Permanent to force the system to start from the PERM image.
See the documentation for the management module to learn more.
2.13.2
Starting the TEMP image
Start the TEMP image before you update the firmware.
Perform the following procedure to start the TEMP image.
1.
Access the Chassis management module.
See the
Management Module Command-Line Interface Reference Guide
or the
Blade
Serial-Over-LAN Setup Guide
for more information.
2.
Click Blade Tasks
→
Configuration
→
Boot Mode.
3.
Click the applicable Escala BL460 blade server in the list of blade servers in the Bull
Blade Chassis - Enterprise.
4.
Select Temporary to force the system to start from the TEMP image.
5.
Restart the blade server.
Содержание Escala BL460
Страница 1: ...Escala BL460 Problem Determination and Service Guide ESCALA Blade REFERENCE 86 A7 81FB 00...
Страница 2: ......
Страница 10: ......
Страница 11: ...Preface vii Safety...
Страница 13: ...Preface ix...
Страница 14: ...x Escala BL460 Problem Determination and Service Guide...
Страница 15: ...Preface xi...
Страница 16: ...xii Escala BL460 Problem Determination and Service Guide...
Страница 17: ...Preface xiii...
Страница 19: ...Preface xv Guidelines for servicing electrical equipment...
Страница 20: ......
Страница 26: ...6 Escala BL460 Problem Determination and Service Guide Figure 1 1 DIMM connectors...
Страница 33: ...Chapter 1 Introduction 13 Figure 1 4 shows individual DIMM connectors Figure 1 4 DIMM connectors...
Страница 220: ...200 Escala BL460 Problem Determination and Service Guide...
Страница 260: ...240 Escala BL460 Problem Determination and Service Guide...
Страница 265: ......
Страница 266: ...BULL CEDOC 357 AVENUE PATTON B P 20845 49008 ANGERS CEDEX 01 FRANCE REFERENCE 86 A7 81FB 00...