48
Escala BL460 -
Problem Determination and Service Guide
•
Follow the suggested actions in the order in which they are listed in the Action column until the problem is
solved. If an action solves the problem, then you can stop performing the remaining actions.
•
See
Chapter 3
, “
Parts listing
,” on page
197
to determine which components are CRUs and which
components are FRUs.
Error code
Description
Action
BA010004
Bootp failed
Perform the following actions that checkpoint
CA00E174 describes:
1. Verify that:
−
The bootp server is correctly configured;
then, retry the operation.
−
The network connections are correct;
then, retry the operation.
2. If the problem persists:
a. Go to “
Checkout procedure
” on page
148
.
b. Replace the system-board and chassis assembly, as
described in “
Replacing the Tier 2 system-board
and chassis assembly
” on page
229
.
BA010005
File transmission (TFTP) failed
Perform the following actions that checkpoint
CA00E174 describes:
1. Verify that:
−
The bootp server is correctly configured;
then, retry the operation.
−
The network connections are correct;
then, retry the operation.
2. If the problem persists:
a. Go to “
Checkout procedure
” on page
148
.
b. Replace the system-board and chassis assembly, as
described in “
Replacing the Tier 2 system-board
and chassis assembly
” on page
229
.
BA010006
The boot image is too large
Start up from another device with a bootable image.
BA010007
The device does not have the required
device_type property.
1. Reboot the blade server.
2. If the problem persists:
a. Go to “
Checkout procedure
” on page
148
.
b. Replace the system-board and chassis assembly, as
described in “
Replacing the Tier 2 system-board
and chassis assembly
” on page
229
.
BA010008
The device_type property for this device
is not supported by the iSCSI initiator
configuration specification.
1. Reboot the blade server.
2. If the problem persists:
a. Go to “
Checkout procedure
” on page
148
.
b. Replace the system-board and chassis assembly, as
described in “
Replacing the Tier 2 system-board
and chassis assembly
” on page
229
.
BA010009
The arguments specified for the ping
function are invalid.
The embedded host Ethernet adapters (HEAs) help provide
iSCSI, which is supported by iSCSI software device drivers
on either AIX or Linux. Verify that all of the iSCSI
configuration arguments on the operating system comply
with the configuration for the iSCSI Host Bus Adapter (HBA),
which is the
iSCSI initiator
.
BA01000A
The itname parameter string exceeds the
maximum length allowed.
The embedded host Ethernet adapters (HEAs) help provide
iSCSI, which is supported by iSCSI software device drivers
on either AIX or Linux. Verify that all of the iSCSI
configuration arguments on the operating system comply
with the configuration for the iSCSI Host Bus Adapter (HBA),
which is the
iSCSI initiator
.
Содержание Escala BL460
Страница 1: ...Escala BL460 Problem Determination and Service Guide ESCALA Blade REFERENCE 86 A7 81FB 00...
Страница 2: ......
Страница 10: ......
Страница 11: ...Preface vii Safety...
Страница 13: ...Preface ix...
Страница 14: ...x Escala BL460 Problem Determination and Service Guide...
Страница 15: ...Preface xi...
Страница 16: ...xii Escala BL460 Problem Determination and Service Guide...
Страница 17: ...Preface xiii...
Страница 19: ...Preface xv Guidelines for servicing electrical equipment...
Страница 20: ......
Страница 26: ...6 Escala BL460 Problem Determination and Service Guide Figure 1 1 DIMM connectors...
Страница 33: ...Chapter 1 Introduction 13 Figure 1 4 shows individual DIMM connectors Figure 1 4 DIMM connectors...
Страница 220: ...200 Escala BL460 Problem Determination and Service Guide...
Страница 260: ...240 Escala BL460 Problem Determination and Service Guide...
Страница 265: ......
Страница 266: ...BULL CEDOC 357 AVENUE PATTON B P 20845 49008 ANGERS CEDEX 01 FRANCE REFERENCE 86 A7 81FB 00...