Chapter 2. Diagnostics
141
2.4.3.4
SCSD devices SRNs (ssss-102 through ssss-640)
These service request numbers (SRNs) identify a SCSD (Self-Configuring SCSI Device)
problem.
Use
Table 2-25
to identify an SRN when you suspect a SAS hard disk or Solid State Disk
(SSD) device problem. Replace the parts in the order that the failing function codes (FFCs)
are listed.
Notes
•
Some SRNs might have 4 digits rather than 3 digits after the dash (–).
•
The
ssss
before the dash (–) represents the 3 digit or 4 digit SCSI SRN.
Table 2-25.
ssss-102 through ssss-640 SRNs
SRN
FFC
Description and action
ssss-102
ssss
An unrecoverable media error occurred.
1. Check the management-module event log. If an error was recorded by the system,
see “
POST progress codes (checkpoints)
” on page
71
.
2. Replace any parts reported by the diagnostic program.
3. Replace the system board and chassis assembly, as described in “
Replacing the Tier
2 system-board and chassis assembly
” on page
229
.
ssss-104
ssss
The motor failed to restart.
1. Check the management-module event log. If an error was recorded by the system,
see “
POST progress codes (checkpoints)
” on page
71
.
2. Replace any parts reported by the diagnostic program.
3. Replace the system board and chassis assembly, as described in “
Replacing the Tier
2 system-board and chassis assembly
” on page
229
.
ssss-105
ssss
The drive did not become ready.
1. Check the management-module event log. If an error was recorded by the system,
see “
POST progress codes (checkpoints)
” on page
71
.
2. Replace any parts reported by the diagnostic program.
3. Replace the system board and chassis assembly, as described in “
Replacing the Tier
2 system-board and chassis assembly
” on page
229
.
ssss-106
ssss
The electronics card test failed.
1. Check the management-module event log. If an error was recorded by the system,
see “
POST progress codes (checkpoints)
” on page
71
.
2. Replace any parts reported by the diagnostic program.
3. Replace the system board and chassis assembly, as described in “
Replacing the Tier
2 system-board and chassis assembly
” on page
229
.
ssss-108
ssss
The bus test failed.
1. Check the management-module event log. If an error was recorded by the system,
see “
POST progress codes (checkpoints)
” on page
71
.
2. Replace any parts reported by the diagnostic program.
3. Replace the system board and chassis assembly, as described in “
Replacing the Tier
2 system-board and chassis assembly
” on page
229
.
Содержание Escala BL460
Страница 1: ...Escala BL460 Problem Determination and Service Guide ESCALA Blade REFERENCE 86 A7 81FB 00...
Страница 2: ......
Страница 10: ......
Страница 11: ...Preface vii Safety...
Страница 13: ...Preface ix...
Страница 14: ...x Escala BL460 Problem Determination and Service Guide...
Страница 15: ...Preface xi...
Страница 16: ...xii Escala BL460 Problem Determination and Service Guide...
Страница 17: ...Preface xiii...
Страница 19: ...Preface xv Guidelines for servicing electrical equipment...
Страница 20: ......
Страница 26: ...6 Escala BL460 Problem Determination and Service Guide Figure 1 1 DIMM connectors...
Страница 33: ...Chapter 1 Introduction 13 Figure 1 4 shows individual DIMM connectors Figure 1 4 DIMM connectors...
Страница 220: ...200 Escala BL460 Problem Determination and Service Guide...
Страница 260: ...240 Escala BL460 Problem Determination and Service Guide...
Страница 265: ......
Страница 266: ...BULL CEDOC 357 AVENUE PATTON B P 20845 49008 ANGERS CEDEX 01 FRANCE REFERENCE 86 A7 81FB 00...