Chapter 2. Diagnostics
47
•
Follow the suggested actions in the order in which they are listed in the Action column until the problem is
solved. If an action solves the problem, then you can stop performing the remaining actions.
•
See
Chapter 3
, “
Parts listing
,” on page
197
to determine which components are CRUs and which
components are FRUs.
Error code
Description
Action
BA00E843
Failure when initializing the interface to
AIX or Linux
1. Go to “
Checkout procedure
” on page
148
.
2. Replace the system-board and chassis assembly, as
described in “
Replacing the Tier 2 system-board and
chassis assembly
” on page
229
.
BA00E850
Failure when initializing dynamic
reconfiguration
1. Go to “
Checkout procedure
” on page
148
.
2. Replace the system-board and chassis assembly, as
described in “
Replacing the Tier 2 system-board and
chassis assembly
” on page
229
.
BA00E860
Failure when initializing sensors
1. Go to “
Checkout procedure
” on page
148
.
2. Replace the system-board and chassis assembly, as
described in “
Replacing the Tier 2 system-board and
chassis assembly
” on page
229
.
BA010000
There is insufficient information to boot
the systems
1. Go to “
Checkout procedure
” on page
148
.
2. Replace the system-board and chassis assembly, as
described in “
Replacing the Tier 2 system-board and
chassis assembly
” on page
229
.
BA010001
The client IP address is already in use by
another network device
Verify that all of the IP addresses on the network are unique;
then, retry the operation.
BA010002
Cannot get gateway IP address
Perform the following actions that checkpoint CA00E174
describes:
1. Verify that:
−
The bootp server is correctly configured;
then, retry the operation.
−
The network connections are correct;
then, retry the operation.
2. If the problem persists:
a. Go to “
Checkout procedure
” on page
148
.
b. Replace the system-board and chassis assembly, as
described in “
Replacing the Tier 2 system-board
and chassis assembly
” on page
229
.
BA010003
Cannot get server hardware address
Perform the following actions that checkpoint
CA00E174 describes:
1. Verify that:
−
The bootp server is correctly configured;
then, retry the operation.
−
The network connections are correct;
then, retry the operation.
2. If the problem persists:
a. Go to “
Checkout procedure
” on page
148
.
b. Replace the system-board and chassis assembly, as
described in “
Replacing the Tier 2 system-board
and chassis assembly
” on page
229
.
Содержание Escala BL460
Страница 1: ...Escala BL460 Problem Determination and Service Guide ESCALA Blade REFERENCE 86 A7 81FB 00...
Страница 2: ......
Страница 10: ......
Страница 11: ...Preface vii Safety...
Страница 13: ...Preface ix...
Страница 14: ...x Escala BL460 Problem Determination and Service Guide...
Страница 15: ...Preface xi...
Страница 16: ...xii Escala BL460 Problem Determination and Service Guide...
Страница 17: ...Preface xiii...
Страница 19: ...Preface xv Guidelines for servicing electrical equipment...
Страница 20: ......
Страница 26: ...6 Escala BL460 Problem Determination and Service Guide Figure 1 1 DIMM connectors...
Страница 33: ...Chapter 1 Introduction 13 Figure 1 4 shows individual DIMM connectors Figure 1 4 DIMM connectors...
Страница 220: ...200 Escala BL460 Problem Determination and Service Guide...
Страница 260: ...240 Escala BL460 Problem Determination and Service Guide...
Страница 265: ......
Страница 266: ...BULL CEDOC 357 AVENUE PATTON B P 20845 49008 ANGERS CEDEX 01 FRANCE REFERENCE 86 A7 81FB 00...