34
Escala BL460 -
Problem Determination and Service Guide
•
Follow the suggested actions in the order in which they are listed in the Action column until the problem is
solved. If an action solves the problem, then you can stop performing the remaining actions.
•
See
Chapter 3
, “
Parts listing
,” on page
197
to determine which components are CRUs and which
components are FRUs.
B200 xxxx
Error codes
Description Action
3081
During the startup of a partition, the startup
did not complete due to a copy error.
Check for server firmware updates; then, install the updates
if available.
3084
A problem occurred during the startup of a
partition.
The adapter type might not be supported.
Verify that the adapter type is supported.
3088
Informational system log entry only.
No corrective action is required.
308C
A problem occurred during the startup of a
partition.
The adapter type cannot be determined.
Verify that a valid I/O Load Source is tagged.
3090
A problem occurred during the startup of a
partition.
Go to “
Firmware problem isolation
” on page
185
.
3110
A problem occurred during the startup of a
partition.
Go to “
Firmware problem isolation
” on page
185
.
3113
A problem occurred during the startup of a
partition.
Look for B7xx xxxx errors and resolve them.
3114
A problem occurred during the startup of a
partition.
Look for other errors and resolve them.
3120
Informational system log entry only.
No corrective action is required.
3123
Informational system log entry only.
No corrective action is required.
3125
During the startup of a partition, the blade
server firmware could not obtain a segment
of main storage within the blade server to
use for managing the creation of a
partition.
Check for server firmware updates; then, install the updates
if available.
3128
A problem occurred during the startup of a
partition. A return code for an unexpected
failure was returned when attempting to
query the load source path.
Look for and resolve B700 69xx errors.
3130
A problem occurred during the startup of a
partition.
Check for server firmware updates; then, install the updates
if available.
3135
A problem occurred during the startup of a
partition.
Check for server firmware updates; then, install the updates
if available.
3140
A problem occurred during the startup of a
partition. This is a configuration problem in
the partition.
Reconfigure the partition to include the intended load source
path.
3141
Informational system log entry only.
No corrective action is required.
3142
Informational system log entry only.
No corrective action is required.
3143
Informational system log entry only.
No corrective action is required.
3144
Informational system log entry only.
No corrective action is required.
3145
Informational system log entry only.
No corrective action is required.
3200
Informational system log entry only.
No corrective action is required.
4158
Informational system log entry only.
No corrective action is required.
4400
A problem occurred during the startup of a
partition.
Check for server firmware updates; then, install the updates
if available.
5106
A problem occurred during the startup of a
partition. There is not enough space to
contain the partition main storage dump.
The startup will not continue.
Verify that there is sufficient memory available to start the
partition as it is configured. If there is already enough
memory, then go to “
Firmware problem isolation
” on page
185
.
5109
A problem occurred during the startup of a
partition. There was a partition main
storage dump problem. The startup will not
continue.
Go to “
Firmware problem isolation
” on page
185
.
Содержание Escala BL460
Страница 1: ...Escala BL460 Problem Determination and Service Guide ESCALA Blade REFERENCE 86 A7 81FB 00...
Страница 2: ......
Страница 10: ......
Страница 11: ...Preface vii Safety...
Страница 13: ...Preface ix...
Страница 14: ...x Escala BL460 Problem Determination and Service Guide...
Страница 15: ...Preface xi...
Страница 16: ...xii Escala BL460 Problem Determination and Service Guide...
Страница 17: ...Preface xiii...
Страница 19: ...Preface xv Guidelines for servicing electrical equipment...
Страница 20: ......
Страница 26: ...6 Escala BL460 Problem Determination and Service Guide Figure 1 1 DIMM connectors...
Страница 33: ...Chapter 1 Introduction 13 Figure 1 4 shows individual DIMM connectors Figure 1 4 DIMM connectors...
Страница 220: ...200 Escala BL460 Problem Determination and Service Guide...
Страница 260: ...240 Escala BL460 Problem Determination and Service Guide...
Страница 265: ......
Страница 266: ...BULL CEDOC 357 AVENUE PATTON B P 20845 49008 ANGERS CEDEX 01 FRANCE REFERENCE 86 A7 81FB 00...