138
Escala BL460 -
Problem Determination and Service Guide
SRN Description
FRU/action
A15-24x
Power Fault specifically due to internal
battery failure.
1. Check the management-module event log; if an error
was recorded by the system, see “
POST progress
codes (checkpoints)
” on page
71
.
2. If no entry is found, replace the system-board and
chassis assembly.
A15-50x
Recoverable errors on resource indicate a
trend toward an unrecoverable error.
However, the resource could not be
deconfigured and is still in use.
The system is operating with the potential for
an unrecoverable error.
1. If repair is not immediately available, reboot and the
resource will be deconfigured; operations can
continue in a degraded mode.
2. Check the management-module event log; if an error
was recorded by the system, see “
POST progress
codes (checkpoints)
” on page
71
.
3. If no entry is found, replace the system-board and
chassis assembly.
A1D-00x
A non-critical error has been detected. Error
log analysis indicates an error detected by
the Service Processor, but the failure could
not be isolated.
1. Check the management-module event log; if an error
was recorded by the system, see “
POST progress
codes (checkpoints)
” on page
71
.
2. If no entry is found, replace the system-board and
chassis assembly.
A1D-02x
A non-critical error has been detected, an
I/O (I2C) general bus error.
1. Check the management-module event log; if an error
was recorded by the system, see “
POST progress
codes (checkpoints)
” on page
71
.
2. If no entry is found, replace the system-board and
chassis assembly.
A1D-04x
A non-critical error has been detected, an
internal service processor memory error.
1. Check the management-module event log; if an error
was recorded by the system, see “
POST progress
codes (checkpoints)
” on page
71
.
2. If no entry is found, replace the system-board and
chassis assembly.
A1D-05x
A non-critical error has been detected, a
service processor error accessing special
registers.
1. Check the management-module event log; if an error
was recorded by the system, see “
POST progress
codes (checkpoints)
” on page
71
.
2. If no entry is found, replace the system-board and
chassis assembly.
A1D-06x
A non-critical error has been detected, a
service processor reports unknown
communication error.
1. Check the management-module event log; if an error
was recorded by the system, see “
POST progress
codes (checkpoints)
” on page
71
.
2. If no entry is found, replace the system-board and
chassis assembly.
A1D-07x
A non-critical error has been detected:
Internal service processor firmware error or
incorrect version.
1. Check the management-module event log; if an error
was recorded by the system, see “
POST progress
codes (checkpoints)
” on page
71
.
2. If no entry is found, replace the system-board and
chassis assembly.
A1D-08x
A non-critical error has been detected,
another internal service processor hardware
error.
1. Check the management-module event log; if an error
was recorded by the system, see “
POST progress
codes (checkpoints)
” on page
71
.
2. If no entry is found, replace the system-board and
chassis assembly.
A1D-09x
A non-critical error has been detected, a
service processor error accessing vital
product data EEPROM.
1. Check the management-module event log; if an error
was recorded by the system, see “
POST progress
codes (checkpoints)
” on page
71
.
2. If no entry is found, replace the system-board and
chassis assembly.
A1D-12x
A non-critical error has been detected, a
service processor error accessing fan sensor.
1. Check the management-module event log; if an error
was recorded by the system, see “
POST progress
codes (checkpoints)
” on page
71
.
2. If no entry is found, replace the system-board and
chassis assembly.
Содержание Escala BL460
Страница 1: ...Escala BL460 Problem Determination and Service Guide ESCALA Blade REFERENCE 86 A7 81FB 00...
Страница 2: ......
Страница 10: ......
Страница 11: ...Preface vii Safety...
Страница 13: ...Preface ix...
Страница 14: ...x Escala BL460 Problem Determination and Service Guide...
Страница 15: ...Preface xi...
Страница 16: ...xii Escala BL460 Problem Determination and Service Guide...
Страница 17: ...Preface xiii...
Страница 19: ...Preface xv Guidelines for servicing electrical equipment...
Страница 20: ......
Страница 26: ...6 Escala BL460 Problem Determination and Service Guide Figure 1 1 DIMM connectors...
Страница 33: ...Chapter 1 Introduction 13 Figure 1 4 shows individual DIMM connectors Figure 1 4 DIMM connectors...
Страница 220: ...200 Escala BL460 Problem Determination and Service Guide...
Страница 260: ...240 Escala BL460 Problem Determination and Service Guide...
Страница 265: ......
Страница 266: ...BULL CEDOC 357 AVENUE PATTON B P 20845 49008 ANGERS CEDEX 01 FRANCE REFERENCE 86 A7 81FB 00...