Chapter 2. Diagnostics
45
Table 2-13. BA000010 to BA400002 Partition firmware SRCs
•
Follow the suggested actions in the order in which they are listed in the Action column until the problem is
solved. If an action solves the problem, then you can stop performing the remaining actions.
•
See
Chapter 3
, “
Parts listing
,” on page
197
to determine which components are CRUs and which
components are FRUs.
Error code
Description
Action
BA000010
The device data structure is corrupted
1. Go to “
Checkout procedure
” on page
148
.
2. Replace the system-board and chassis assembly, as
described in “
Replacing the Tier 2 system-board and
chassis assembly
” on page
229
.
BA000020
Incompatible firmware levels were found
1. Reboot the blade server.
2. If the problem persists:
a. Go to “
Checkout procedure
” on page
148
.
b. Replace the system-board and chassis assembly, as
described in “
Replacing the Tier 2 system-board
and chassis assembly
” on page
229
.
BA000030
An lpevent communication failure
occurred
1. Go to “
Checkout procedure
” on page
148
.
2. Replace the system-board and chassis assembly, as
described in “
Replacing the Tier 2 system-board and
chassis assembly
” on page
229
.
BA000031
An lpevent communication failure
occurred
1. Go to “
Checkout procedure
” on page
148
.
2. Replace the system-board and chassis assembly, as
described in “
Replacing the Tier 2 system-board and
chassis assembly
” on page
229
.
BA000032
The firmware failed to register the lpevent
queues
1. Reboot the blade server.
2. If the problem persists:
a. Go to “
Checkout procedure
” on page
148
.
b. Replace the system-board and chassis assembly, as
described in “
Replacing the Tier 2 system-board
and chassis assembly
” on page
229
.
BA000034
The firmware failed to exchange capacity
and allocate lpevents
1. Reboot the blade server.
2. If the problem persists:
a. Go to “
Checkout procedure
” on page
148
.
b. Replace the system-board and chassis assembly, as
described in “
Replacing the Tier 2 system-board
and chassis assembly
” on page
229
.
BA000038
The firmware failed to exchange virtual
continuation events
1. Reboot the blade server.
2. If the problem persists:
a. Go to “
Checkout procedure
” on page
148
.
b. Replace the system-board and chassis assembly, as
described in “
Replacing the Tier 2 system-board
and chassis assembly
” on page
229
.
BA000040
The firmware was unable to obtain the
RTAS code lid details
1. Reboot the blade server.
2. If the problem persists:
a. Go to “
Checkout procedure
” on page
148
.
b. Replace the system-board and chassis assembly, as
described in “
Replacing the Tier 2 system-board
and chassis assembly
” on page
229
.
BA000050
The firmware was unable to load the
RTAS code lid
1. Reboot the blade server.
2. If the problem persists:
a. Go to “
Checkout procedure
” on page
148
.
b. Replace the system-board and chassis assembly, as
described in “
Replacing the Tier 2 system-board
and chassis assembly
” on page
229
.
Содержание Escala BL460
Страница 1: ...Escala BL460 Problem Determination and Service Guide ESCALA Blade REFERENCE 86 A7 81FB 00...
Страница 2: ......
Страница 10: ......
Страница 11: ...Preface vii Safety...
Страница 13: ...Preface ix...
Страница 14: ...x Escala BL460 Problem Determination and Service Guide...
Страница 15: ...Preface xi...
Страница 16: ...xii Escala BL460 Problem Determination and Service Guide...
Страница 17: ...Preface xiii...
Страница 19: ...Preface xv Guidelines for servicing electrical equipment...
Страница 20: ......
Страница 26: ...6 Escala BL460 Problem Determination and Service Guide Figure 1 1 DIMM connectors...
Страница 33: ...Chapter 1 Introduction 13 Figure 1 4 shows individual DIMM connectors Figure 1 4 DIMM connectors...
Страница 220: ...200 Escala BL460 Problem Determination and Service Guide...
Страница 260: ...240 Escala BL460 Problem Determination and Service Guide...
Страница 265: ......
Страница 266: ...BULL CEDOC 357 AVENUE PATTON B P 20845 49008 ANGERS CEDEX 01 FRANCE REFERENCE 86 A7 81FB 00...