
38
Escala BL460 -
Problem Determination and Service Guide
•
Follow the suggested actions in the order in which they are listed in the Action column until the problem is
solved. If an action solves the problem, then you can stop performing the remaining actions.
•
See
Chapter 3
, “
Parts listing
,” on page
197
to determine which components are CRUs and which
components are FRUs.
B200 xxxx
Error codes
Description Action
B215
A problem occurred after a partition ended
abnormally.
There was a communications problem
between this partition’s service processor
and the platform’s service processor.
Restart the platform.
C1F0
An internal system firmware error occurred
during a partition shutdown or a restart.
Go to “
Firmware problem isolation
” on page
185
.
D150
A partition ended abnormally; there was a
communications problem between this
partition and the code that handles
resource allocation.
Check for server firmware updates; then, install the updates
if available.
E0AA
A problem occurred during the power off of
a partition.
Go to “
Firmware problem isolation
” on page
185
.
F001
A problem occurred during the startup of a
partition. An operation has timed out.
Look for other errors and resolve them.
F003
During the startup of a partition, the
partition processor(s) did not start
the firmware within the time-out window.
Collect the partition dump information; then, go to
“
Firmware problem isolation
” on page
185
.
F004
Informational system log entry only.
No corrective action is required.
F005
Informational system log entry only.
No corrective action is required.
F006
During the startup of a partition, the code
load operation for the partition startup
timed out.
1. Check the error logs and take the actions for the error
codes that are found.
2. Go to “
Firmware problem isolation
” on page
185
.
F007
During a shutdown of the partition, a time-
out occurred while trying to stop a
partition.
Check for server firmware updates; then, install the updates
if available.
F008
Informational system log entry only.
No corrective action is required.
F009
Informational system log entry only.
No corrective action is required.
F00A
Informational system log entry only.
No corrective action is required.
F00B
Informational system log entry only.
No corrective action is required.
F00C
Informational system log entry only.
No corrective action is required.
F00D
Informational system log entry only.
No corrective action is required.
2.4.1.9
B700xxxx Licensed internal code SRCs
A B700xxxx system reference code (SRC) is an error code that is related to licensed
internal code.
Table 2-12
describes the error codes that may be displayed if POST detects a problem.
Suggested actions to correct the problem are also described.
Note
For problems persisting after completing the suggested actions, see “
Checkout procedure
”
on page
148
and “
Solving undetermined problems
” on page
194
.
Содержание Escala BL460
Страница 1: ...Escala BL460 Problem Determination and Service Guide ESCALA Blade REFERENCE 86 A7 81FB 00...
Страница 2: ......
Страница 10: ......
Страница 11: ...Preface vii Safety...
Страница 13: ...Preface ix...
Страница 14: ...x Escala BL460 Problem Determination and Service Guide...
Страница 15: ...Preface xi...
Страница 16: ...xii Escala BL460 Problem Determination and Service Guide...
Страница 17: ...Preface xiii...
Страница 19: ...Preface xv Guidelines for servicing electrical equipment...
Страница 20: ......
Страница 26: ...6 Escala BL460 Problem Determination and Service Guide Figure 1 1 DIMM connectors...
Страница 33: ...Chapter 1 Introduction 13 Figure 1 4 shows individual DIMM connectors Figure 1 4 DIMM connectors...
Страница 220: ...200 Escala BL460 Problem Determination and Service Guide...
Страница 260: ...240 Escala BL460 Problem Determination and Service Guide...
Страница 265: ......
Страница 266: ...BULL CEDOC 357 AVENUE PATTON B P 20845 49008 ANGERS CEDEX 01 FRANCE REFERENCE 86 A7 81FB 00...