Chapter 2. Diagnostics
175
•
Follow the suggested actions in the order in which they are listed in the Action column until the problem is solved.
•
See
Chapter 3
, “
Parts listing
,” on page
197
to determine which components are CRUs and which components are
FRUs.
•
If an action step is preceded by “(Trained service technician only),” that step must be performed only by a trained
service technician.
Isolation
Procedure Code
Symptom Action
FSPSP24
The system is running
degraded. Array bit
steering may be able
to correct this problem
without replacing
hardware.
1. Power off the blade server, as described in “
Turning off the blade server
”
on page
11
.
2. Remove the blade server from the Bull Blade Chassis - Enterprise and
reinsert the blade server into the Bull Blade Chassis - Enterprise.
3. Power on the blade server, as described in “
Turning on the blade
server
” on page
10
.
4. If the problem persists, replace the CRU that is called out after this
procedure.
FSPSP27
An attention line has
been detected as
having a problem.
Replace the CRU that is called out before this FSPSP27 call. If the CRU does
not correct the problem, call Bull Support.
FSPSP28
The resource ID (RID)
of the CRU could not
be found in the Vital
Product Data (VPD)
table.
1. Find another callout that reads FSPxxxx where xxxx is a 4-digit hex
number that represents the resource ID. Record the resource ID and the
model of the system.
2. Call Bull Support to find out what CRU the resource ID represents.
3. Replace the CRU that the resource ID represents.
FSPSP29
The system has
detected that all I/O
bridges are missing
from the system
configuration.
Replace the system board and chassis assembly, as described in
“
Replacing the Tier 2 system-board and chassis assembly
” on page
229
.
FSPSP30
A problem has been
encountered accessing
the management card
or the VPD data found
on the management
card has been
corrupted.
This error occurred
before VPD collection
was completed, so no
location codes have
been created.
1. Replace the management card, as described in “
Removing the
management card
” on page
216
and “
Installing the management card
”
on page
217
.
2. After replacing the card and installing the blade server in the chassis unit
and before rebooting the blade server or performing other operations,
ensure that the initialization of the management card VPD occurs by
waiting for the management module to discover the blade server.
Otherwise, the system might fail to IPL.
3. If the problem persists, Replace the system board and chassis assembly,
as described in “
Replacing the Tier 2 system-board and chassis
assembly
” on page
229
.
FSPSP31
The service processor
has detected that one
or more of the
required fields in the
system VPD has not
initialized.
1. When the system reaches the SMS, set the system VPD values that are
required, which automatically resets the service processor.
2. Power on the blade server, as described in “
Turning on the blade
server
” on page
10
.
Содержание Escala BL460
Страница 1: ...Escala BL460 Problem Determination and Service Guide ESCALA Blade REFERENCE 86 A7 81FB 00...
Страница 2: ......
Страница 10: ......
Страница 11: ...Preface vii Safety...
Страница 13: ...Preface ix...
Страница 14: ...x Escala BL460 Problem Determination and Service Guide...
Страница 15: ...Preface xi...
Страница 16: ...xii Escala BL460 Problem Determination and Service Guide...
Страница 17: ...Preface xiii...
Страница 19: ...Preface xv Guidelines for servicing electrical equipment...
Страница 20: ......
Страница 26: ...6 Escala BL460 Problem Determination and Service Guide Figure 1 1 DIMM connectors...
Страница 33: ...Chapter 1 Introduction 13 Figure 1 4 shows individual DIMM connectors Figure 1 4 DIMM connectors...
Страница 220: ...200 Escala BL460 Problem Determination and Service Guide...
Страница 260: ...240 Escala BL460 Problem Determination and Service Guide...
Страница 265: ......
Страница 266: ...BULL CEDOC 357 AVENUE PATTON B P 20845 49008 ANGERS CEDEX 01 FRANCE REFERENCE 86 A7 81FB 00...