110
Escala BL460 -
Problem Determination and Service Guide
2.4.3.2
101-711 through FFC-725 SRNs
AIX might generate service request numbers (SRNs) from 101-711 to FFC-725.
Replace any parts in the order that the codes are listed in
Table 2-22
.
Note
An
x
in the following SRNs represents a digit or character that might have any value.
Table 2-22.
101-711 through FFC-725 SRNs
SRN FFC
Description and Action
101-711 to
101-726
711 to 726
The system hung while trying to configure an unknown resource.
1. Run the stand-alone diagnostics problem determination procedure.
2. If the problem remains, refer to “
Failing function codes 151 through 2D02
” on page
144
to find the FFC that matches the last three digits of the SRN.
3. Suspect the device adapter or device itself.
101-888
210 227
The system does not IPL. Go to “
Performing the checkout procedure
” on page
149
or
undetermined problem procedure.
101-2020
The system hung while trying to configure the InfiniBand Communication Manager. This
problem may be attributed to software. Report this problem to the AIX Support Center.
101-2021
The system hung while trying to configure the InfiniBand TCP/IP Interface. This problem
may be attributed to software. Report this problem to the AIX Support Center.
101-xxxx
xxxx
The system hung while configuring a resource. The last three or four digits after the dash (-)
identify the failing function code for the resource being configured. Go to undetermined
problem procedure.
103-151
151
The time-of-day battery failed.
1. Go to “
Removing the battery
” on page
224
to start the battery replacement procedure.
2. Go to “
Installing the battery
” on page
225
to complete the procedure.
109-200
The system crashed while you were running it.
1. Go to “
Performing the checkout procedure
” on page
149
2. If the 8-digit error and location codes were NOT reported, run AIX diagnostics in
problem determination procedure and record and report the 8-digit error and location
codes for this SRN.
110-101
The diagnostics did not detect an installed resource. If this SRN appeared when running
concurrent diagnostics, then run concurrent diagnostics using the diag -a command.
110-921 to
110-926
812 xxx
The system halted while diagnostics were executing.
Go to “
Performing the checkout procedure
” on page
149
or problem resolution.
Note: xxx corresponds to the last three digits of the SRN.
110-935
812
The system halted while diagnostics were executing. Use the problem determination
procedure.
110-xxxx
xxxx 221
The system halted while diagnostics were executing.
Note: xxxx corresponds to the last three or four digits of the SRN following the dash (-).
1. If your 110 SRN is not listed, substitute the last three or four digits of the SRN for xxxx
and go to “
Failing function codes 151 through 2D02
” on page
144
to identify the
failing feature.
2. Run stand-alone diagnostics and the problem determination procedure for your
operating system.
111-107
A machine check occurred. Go to “
Performing the checkout procedure
” on page
149
111-108
An encoded SRN was displayed. Go to “
Performing the checkout procedure
” on page
149
111-121
There is a display problem. Go to “
Performing the checkout procedure
” on page
149
Содержание Escala BL460
Страница 1: ...Escala BL460 Problem Determination and Service Guide ESCALA Blade REFERENCE 86 A7 81FB 00...
Страница 2: ......
Страница 10: ......
Страница 11: ...Preface vii Safety...
Страница 13: ...Preface ix...
Страница 14: ...x Escala BL460 Problem Determination and Service Guide...
Страница 15: ...Preface xi...
Страница 16: ...xii Escala BL460 Problem Determination and Service Guide...
Страница 17: ...Preface xiii...
Страница 19: ...Preface xv Guidelines for servicing electrical equipment...
Страница 20: ......
Страница 26: ...6 Escala BL460 Problem Determination and Service Guide Figure 1 1 DIMM connectors...
Страница 33: ...Chapter 1 Introduction 13 Figure 1 4 shows individual DIMM connectors Figure 1 4 DIMM connectors...
Страница 220: ...200 Escala BL460 Problem Determination and Service Guide...
Страница 260: ...240 Escala BL460 Problem Determination and Service Guide...
Страница 265: ......
Страница 266: ...BULL CEDOC 357 AVENUE PATTON B P 20845 49008 ANGERS CEDEX 01 FRANCE REFERENCE 86 A7 81FB 00...