Chapter 2. Diagnostics
33
•
Follow the suggested actions in the order in which they are listed in the Action column until the problem is
solved. If an action solves the problem, then you can stop performing the remaining actions.
•
See
Chapter 3
, “
Parts listing
,” on page
197
to determine which components are CRUs and which
components are FRUs.
B200 xxxx
Error codes
Description Action
1282
A problem occurred during the startup of a
partition.
Go to “
Firmware problem isolation
” on page
185
.
1320
A problem occurred during the startup of a
partition.
No default load source was selected. The
startup will attempt to continue, but there
may not be enough information to find the
correct load source.
Configure a load source for the partition. Then restart the
partition.
1321
A problem occurred during the startup of a
partition.
Verify that the correct slot is specified for the load source.
Then restart the partition.
1322
In the partition startup, code failed during a
check of the load source path.
Verify that the path for the load source is specified correctly.
Then restart the partition.
2048
A problem occurred during a partition
Main Storage Dump. A mainstore dump
startup did not complete due to a copy
error.
Go to “
Firmware problem isolation
” on page
185
.
2054
A problem occurred during a partition
Main Storage Dump. A mainstore dump
startup did not complete due to a
configuration mismatch.
Go to “
Firmware problem isolation
” on page
185
.
2058
A problem occurred during a partition
Main Storage Dump. A mainstore dump
startup did not complete due to a copy
error.
Go to “
Firmware problem isolation
” on page
185
.
2210
Informational system log entry only.
No corrective action is required.
2220
Informational system log entry only.
No corrective action is required.
2250
During the startup of a partition, an attempt
to toggle the power state of a slot has
failed.
Check for server firmware updates; then, install the updates
if available.
2260
During the startup of a partition, the
partition firmware attempted an operation
that failed.
Go to “
Firmware problem isolation
” on page
185
.
2300
During the startup of a partition, an attempt
to toggle the power state of a slot has
failed.
Check for server firmware updates; then, install the updates
if available.
2310
During the startup of a partition, the
partition firmware attempted an operation
that failed.
Go to “
Firmware problem isolation
” on page
185
.
2320
During the startup of a partition, the
partition firmware attempted an operation
that failed.
Go to “
Firmware problem isolation
” on page
185
.
2425
During the startup of a partition, the
partition firmware attempted an operation
that failed.
Go to “
Firmware problem isolation
” on page
185
.
2426
During the startup of a partition, the
partition firmware attempted an operation
that failed.
Go to “
Firmware problem isolation
” on page
185
.
2475
During the startup of a partition, a slot that
was needed for the partition was either
empty or the device in the slot has failed.
Check for server firmware updates; then, install the updates
if available.
2485
During the startup of a partition, the
partition firmware attempted an operation
that failed.
Go to “
Firmware problem isolation
” on page
185
.
3000
Informational system log entry only.
No corrective action is required.
Содержание Escala BL460
Страница 1: ...Escala BL460 Problem Determination and Service Guide ESCALA Blade REFERENCE 86 A7 81FB 00...
Страница 2: ......
Страница 10: ......
Страница 11: ...Preface vii Safety...
Страница 13: ...Preface ix...
Страница 14: ...x Escala BL460 Problem Determination and Service Guide...
Страница 15: ...Preface xi...
Страница 16: ...xii Escala BL460 Problem Determination and Service Guide...
Страница 17: ...Preface xiii...
Страница 19: ...Preface xv Guidelines for servicing electrical equipment...
Страница 20: ......
Страница 26: ...6 Escala BL460 Problem Determination and Service Guide Figure 1 1 DIMM connectors...
Страница 33: ...Chapter 1 Introduction 13 Figure 1 4 shows individual DIMM connectors Figure 1 4 DIMM connectors...
Страница 220: ...200 Escala BL460 Problem Determination and Service Guide...
Страница 260: ...240 Escala BL460 Problem Determination and Service Guide...
Страница 265: ......
Страница 266: ...BULL CEDOC 357 AVENUE PATTON B P 20845 49008 ANGERS CEDEX 01 FRANCE REFERENCE 86 A7 81FB 00...