Chapter 2. Diagnostics
37
•
Follow the suggested actions in the order in which they are listed in the Action column until the problem is
solved. If an action solves the problem, then you can stop performing the remaining actions.
•
See
Chapter 3
, “
Parts listing
,” on page
197
to determine which components are CRUs and which
components are FRUs.
B200 xxxx
Error codes
Description Action
8114
During the startup of a partition, there was
a failure verifying the VPD for the partition
resources during startup.
Check for server firmware updates; then, install the updates
if available.
8115
During the startup of a partition, there was
a low level
partition-to-partition communication failure.
Check for server firmware updates; then, install the updates
if available.
8117
During the startup of a partition, the
partition did not start up due to a system
firmware error.
Check for server firmware updates; then, install the updates
if available.
8121
During the startup of a partition, the
partition did not start up due to a system
firmware error.
Go to “
Firmware problem isolation
” on page
185
.
8123
During the startup of a partition, the
partition did not start up due to a system
firmware error.
Go to “
Firmware problem isolation
” on page
185
.
8125
During the startup of a partition, the
partition did not start up due to a system
firmware error.
Go to “
Firmware problem isolation
” on page
185
.
8127
During the startup of a partition, the
partition did not start up due to a system
firmware error.
Go to “
Firmware problem isolation
” on page
185
.
8129
During the startup of a partition, the
partition did not start up due to a system
firmware error.
Go to “
Firmware problem isolation
” on page
185
.
813A
There was a problem establishing a
console.
Go to “
Firmware problem isolation
” on page
185
.
8140
Informational system log entry only.
No corrective action is required.
8141
Informational system log entry only.
No corrective action is required.
8142
Informational system log entry only.
No corrective action is required.
8143
Informational system log entry only.
No corrective action is required.
8144
Informational system log entry only.
No corrective action is required.
8145
Informational system log entry only.
No corrective action is required.
8150
System firmware detected an error.
Collect a platform dump and then go to “
Firmware problem
isolation
” on page
185
.
8151
System firmware detected an error.
Use the Integrated Virtual Manager (IVM) to increase the
Logical Memory Block (LMB) size, and to reduce the number
of virtual devices for the partition.
8152
No active system processors.
Verify that processor resources are assigned to the partition.
8160
A problem occurred during the migration of
a partition.
Contact Bull support, as described in Appendix A, “
Getting
Help and Technical Assistance
”, on page 239.
8161
A problem occurred during the migration of
a partition.
Contact Bull support, as described in Appendix A, “
Getting
Help and Technical Assistance
”, on page 239.
A100
A partition ended abnormally; the partition
could not stay running and shut itself down.
1. Check the error logs and take the actions for the error
codes that are found.
2. Go to “
Firmware problem isolation
” on page
185
.
A101
A partition ended abnormally; the partition
could not stay running and shut itself down.
1. Check the error logs and take the actions for the error
codes that are found.
2. Go to “
Firmware problem isolation
” on page
185
.
A140
A lower priority partition lost a usable
processor to supply it to a higher priority
partition with a bad processor.
Evaluate the entire LPAR configuration. Adjust partition
profiles with the new number of processors available in the
system.
B07B
Informational system log entry only.
No corrective action is required.
Содержание Escala BL460
Страница 1: ...Escala BL460 Problem Determination and Service Guide ESCALA Blade REFERENCE 86 A7 81FB 00...
Страница 2: ......
Страница 10: ......
Страница 11: ...Preface vii Safety...
Страница 13: ...Preface ix...
Страница 14: ...x Escala BL460 Problem Determination and Service Guide...
Страница 15: ...Preface xi...
Страница 16: ...xii Escala BL460 Problem Determination and Service Guide...
Страница 17: ...Preface xiii...
Страница 19: ...Preface xv Guidelines for servicing electrical equipment...
Страница 20: ......
Страница 26: ...6 Escala BL460 Problem Determination and Service Guide Figure 1 1 DIMM connectors...
Страница 33: ...Chapter 1 Introduction 13 Figure 1 4 shows individual DIMM connectors Figure 1 4 DIMM connectors...
Страница 220: ...200 Escala BL460 Problem Determination and Service Guide...
Страница 260: ...240 Escala BL460 Problem Determination and Service Guide...
Страница 265: ......
Страница 266: ...BULL CEDOC 357 AVENUE PATTON B P 20845 49008 ANGERS CEDEX 01 FRANCE REFERENCE 86 A7 81FB 00...