94
Escala BL460 -
Problem Determination and Service Guide
•
If the system hangs on a progress code, follow the suggested actions in the order in which they are listed
in the Action column until the problem is solved. If an action solves the problem, you can stop performing
theremaining actions.
•
See
Chapter 3
, “
Parts listing
,” on page
197
to determine which components are CRUs and which
components are FRUs.
Progress code
Description
Action
CA00E1A4
User requested boot to SMS menus
1. Go to “
Checkout procedure
” on page
148
.
2. Replace the system-board and chassis assembly,
as described in “
Replacing the Tier 2 system-
board and chassis assembly
” on page
229
.
CA00E1A5
User requested boot to open firmware
prompt
1. Go to “
Checkout procedure
” on page
148
.
2. Replace the system-board and chassis assembly,
as described in “
Replacing the Tier 2 system-
board and chassis assembly
” on page
229
.
CA00E1A6
User requested boot using default
service mode boot list
1. Go to “
Checkout procedure
” on page
148
.
2. Replace the system-board and chassis assembly,
as described in “
Replacing the Tier 2 system-
board and chassis assembly
” on page
229
.
CA00E1A7
User requested boot using customized
service mode boot list
1. Go to “
Checkout procedure
” on page
148
.
2. Replace the system-board and chassis assembly,
as described in “
Replacing the Tier 2 system-
board and chassis assembly
” on page
229
.
CA00E1AA
System boot check for NVRAM settings
1. Go to “
Checkout procedure
” on page
148
.
2. Replace the system-board and chassis assembly,
as described in “
Replacing the Tier 2 system-
board and chassis assembly
” on page
229
.
CA00E1AB
System booting using default service
mode boot list
1. Go to “
Checkout procedure
” on page
148
.
2. Replace the system-board and chassis assembly,
as described in “
Replacing the Tier 2 system-
board and chassis assembly
” on page
229
.
CA00E1AC
System booting using customized
service mode boot list
1. Go to “
Checkout procedure
” on page
148
.
2. Replace the system-board and chassis assembly,
as described in “
Replacing the Tier 2 system-
board and chassis assembly
” on page
229
.
CA00E1AD
System booting to the operating system
1. Go to “
Checkout procedure
” on page
148
.
2. Replace the system-board and chassis assembly,
as described in “
Replacing the Tier 2 system-
board and chassis assembly
” on page
229
.
CA00E1AE
System booted to SMS multiboot menu
using NVRAM settings
1. Go to “
Checkout procedure
” on page
148
.
2. Replace the system-board and chassis assembly,
as described in “
Replacing the Tier 2 system-
board and chassis assembly
” on page
229
.
CA00E1AF
System booted to SMS utilities menu
using NVRAM settings
1. Go to “
Checkout procedure
” on page
148
.
2. Replace the system-board and chassis assembly,
as described in “
Replacing the Tier 2 system-
board and chassis assembly
” on page
229
.
CA00E1B1
System booting system-directed boot-
device repair
1. Go to “
Checkout procedure
” on page
148
.
2. Replace the system-board and chassis assembly,
as described in “
Replacing the Tier 2 system-
board and chassis assembly
” on page
229
.
CA00E1B2
XOFF received, waiting for XON
1. Go to “
Checkout procedure
” on page
148
.
2. Replace the system-board and chassis assembly,
as described in “
Replacing the Tier 2 system-
board and chassis assembly
” on page
229
.
Содержание Escala BL460
Страница 1: ...Escala BL460 Problem Determination and Service Guide ESCALA Blade REFERENCE 86 A7 81FB 00...
Страница 2: ......
Страница 10: ......
Страница 11: ...Preface vii Safety...
Страница 13: ...Preface ix...
Страница 14: ...x Escala BL460 Problem Determination and Service Guide...
Страница 15: ...Preface xi...
Страница 16: ...xii Escala BL460 Problem Determination and Service Guide...
Страница 17: ...Preface xiii...
Страница 19: ...Preface xv Guidelines for servicing electrical equipment...
Страница 20: ......
Страница 26: ...6 Escala BL460 Problem Determination and Service Guide Figure 1 1 DIMM connectors...
Страница 33: ...Chapter 1 Introduction 13 Figure 1 4 shows individual DIMM connectors Figure 1 4 DIMM connectors...
Страница 220: ...200 Escala BL460 Problem Determination and Service Guide...
Страница 260: ...240 Escala BL460 Problem Determination and Service Guide...
Страница 265: ......
Страница 266: ...BULL CEDOC 357 AVENUE PATTON B P 20845 49008 ANGERS CEDEX 01 FRANCE REFERENCE 86 A7 81FB 00...