Chapter 2. Diagnostics
115
SRN FFC
Description and Action
651-811
2E2
Under voltage condition was detected
Do the following procedure before replacing any FRUs:
1. Shut the system down.
2. Visually inspect the power cables and reseat the connectors.
3. Run the following command diag -Avd sysplanar0. When the Resource Repair Action
menu displays, select sysplanar0.
651-813
System shutdown due to loss of ac power to the site. System resumed normal operation, no
action required.
651-818
Power fault due to manual activation of power-off request. Resume normal operation.
651-820
2E1
An over-temperature condition was detected.
1. Make sure that:
v The room ambient temperature is within the system operating environment
v There is unrestricted air flow around the system
2. Replace the system-board and chassis assembly.
651-821
2E1
System shutdown due to an over maximum temperature condition being reached.
1. Make sure that:
v The room ambient temperature is within the system operating environment
v There is unrestricted air flow around the system
2. Replace the system-board and chassis assembly.
651-822
2E1
System shutdown due to over temperature condition and fan failure. Use the physical FRU
location(s) as the probable cause(s). Use the physical location codes to replace the FRUs
that are identified on the diagnostics problem report screen.
651-831
2E2
Sensor detected a voltage outside of the normal range. Go to “
Performing the checkout
procedure
” on page
149.
651-832
G2E1
Sensor detected an abnormally high internal temperature. Make sure that:
1. The room ambient temperature is within the system operating environment.
2. There is unrestricted air flow around the system.
3. There are no fan failures.
651-841
152 2E2
Sensor detected a voltage outside of the normal range. Go to “
Performing the checkout
procedure
” on page
149.
651-842
2E1
Sensor detected an abnormally high internal temperature. Make sure that:
1. The room ambient temperature is within the system operating environment.
2. There is unrestricted air flow around the system.
3. All system covers are closed.
4. There are no fan failures.
651-90x
Platform-specific error. Call your support center.
652-600
A non-critical error has been detected: uncorrectable memory or unsupported memory.
Schedule deferred maintenance. Examine the memory modules and determine if they are
supported types. If the modules are supported, then replace the appropriate memory
modules.
652-610
210
A non-critical error has been detected: CPU internal error. Schedule deferred maintenance.
Go to “
Performing the checkout procedure
” on page
149.
652-611
210
A non-critical error has been detected: CPU internal cache or cache controller error.
Schedule deferred maintenance. Go to “
Performing the checkout procedure
” on page
149.
652-612
D01
A non-critical error has been detected: external cache parity or multi-bit ECC error.
Schedule deferred maintenance. Go to “
Performing the checkout procedure
” on page
149.
652-613
D01
A non-critical error has been detected: external cache ECC single-bit error. Schedule
deferred maintenance. Go to “
Performing the checkout procedure
” on page
149.
652-623
2C6
A non-critical error has been detected: correctable error threshold exceeded. Schedule
deferred maintenance. Go to “
Performing the checkout procedure
” on page
149.
652-630
307
A non-critical error has been detected: I/O expansion bus parity error. Schedule deferred
maintenance. Go to “
Performing the checkout procedure
” on page
149.
Содержание Escala BL460
Страница 1: ...Escala BL460 Problem Determination and Service Guide ESCALA Blade REFERENCE 86 A7 81FB 00...
Страница 2: ......
Страница 10: ......
Страница 11: ...Preface vii Safety...
Страница 13: ...Preface ix...
Страница 14: ...x Escala BL460 Problem Determination and Service Guide...
Страница 15: ...Preface xi...
Страница 16: ...xii Escala BL460 Problem Determination and Service Guide...
Страница 17: ...Preface xiii...
Страница 19: ...Preface xv Guidelines for servicing electrical equipment...
Страница 20: ......
Страница 26: ...6 Escala BL460 Problem Determination and Service Guide Figure 1 1 DIMM connectors...
Страница 33: ...Chapter 1 Introduction 13 Figure 1 4 shows individual DIMM connectors Figure 1 4 DIMM connectors...
Страница 220: ...200 Escala BL460 Problem Determination and Service Guide...
Страница 260: ...240 Escala BL460 Problem Determination and Service Guide...
Страница 265: ......
Страница 266: ...BULL CEDOC 357 AVENUE PATTON B P 20845 49008 ANGERS CEDEX 01 FRANCE REFERENCE 86 A7 81FB 00...