66
Escala BL460 -
Problem Determination and Service Guide
•
Follow the suggested actions in the order in which they are listed in the Action column until the problem is
solved. If an action solves the problem, then you can stop performing the remaining actions.
•
See
Chapter 3
, “
Parts listing
,” on page
197
to determine which components are CRUs and which
components are FRUs.
Error code
Description
Action
BA210103
There was a communication failure
between partition firmware and the
hypervisor. There was a failing return
code with the lpevent acknowledgement
from the hypervisor.
1. Review the event log for errors that occurred around the
time of this error.
2. Correct any errors that are found and reboot the blade
server.
3. If the problem persists:
a. Reboot the blade server.
b. If the problem persists:
1) Go to “
Checkout procedure
” on page
148
.
2) Replace the system-board and chassis assembly,
as described in “
Replacing the Tier 2 system-
board and chassis assembly
” on page
229
.
BA220010
There was a partition firmware error
during a USB hotplug probing. USB
hotplug may not work properly on this
partition.
1. Look for EEH-related errors in the event log.
2. Resolve any EEH event log entries that are found.
3. Correct any errors that are found and reboot the blade
server.
4. If the problem persists:
a. Go to “
Checkout procedure
” on page
148
.
b. Replace the system-board and chassis assembly, as
described in “
Replacing the Tier 2 system-board
and chassis assembly
” on page
229
.
BA220020
CRQ registration error; partner vslot may
not be valid
Verify that this client virtual slot device has a valid server
virtual slot device in a hosting partition.
BA278001
Failed to flash firmware: invalid image
file
Download a new firmware update image and retry the
update.
BA278002
Flash file is not designed for this platform
Download a new firmware update image and retry the
update.
BA278003
Unable to lock the firmware update lid
manager
1. Restart the blade server.
2. Verify that the operating system is authorized to update
the firmware. If the system is running multiple partitions,
verify that this partition has service authority.
BA278004
An invalid firmware update lid was
requested
Download a new firmware update image and retry the
update.
BA278005
Failed to flash a firmware update lid
Download a new firmware update image and retry the
update.
BA278006
Unable to unlock the firmware update lid
manager
Restart the blade server.
BA278007
Failed to reboot the system after a
firmware flash update
Restart the blade server.
BA278009
The operating system’s server firmware
update management tools are
incompatible with this system.
Go to the download site at
www14.software.ibm.com/webapp/set2/sas/
f/lopdiags/home.html to download the latest version of the
service aids package for Linux.
BA27800A
The firmware installation failed due to a
hardware error that was reported.
1. Look for hardware errors in the event log.
2. Resolve any hardware errors that are found.
3. If the problem persists:
a. Go to “
Checkout procedure
” on page
148
.
b. Replace the system-board and chassis assembly, as
described in “
Replacing the Tier 2 system-board and
chassis assembly
” on page
229
.
Содержание Escala BL460
Страница 1: ...Escala BL460 Problem Determination and Service Guide ESCALA Blade REFERENCE 86 A7 81FB 00...
Страница 2: ......
Страница 10: ......
Страница 11: ...Preface vii Safety...
Страница 13: ...Preface ix...
Страница 14: ...x Escala BL460 Problem Determination and Service Guide...
Страница 15: ...Preface xi...
Страница 16: ...xii Escala BL460 Problem Determination and Service Guide...
Страница 17: ...Preface xiii...
Страница 19: ...Preface xv Guidelines for servicing electrical equipment...
Страница 20: ......
Страница 26: ...6 Escala BL460 Problem Determination and Service Guide Figure 1 1 DIMM connectors...
Страница 33: ...Chapter 1 Introduction 13 Figure 1 4 shows individual DIMM connectors Figure 1 4 DIMM connectors...
Страница 220: ...200 Escala BL460 Problem Determination and Service Guide...
Страница 260: ...240 Escala BL460 Problem Determination and Service Guide...
Страница 265: ......
Страница 266: ...BULL CEDOC 357 AVENUE PATTON B P 20845 49008 ANGERS CEDEX 01 FRANCE REFERENCE 86 A7 81FB 00...