Chapter 2. Diagnostics
133
SRN Description
FRU/action
A10-210
The processor has been deconfigured. The
system is operating in degraded mode.
1. Check the management-module event log; if an error
was recorded by the system, see “
POST progress
codes (checkpoints)
” on page
71
.
2. If no entry is found, replace the system-board and
chassis assembly.
A11-00x
A non-critical error has been detected. Error
log analysis indicates an error detected by
the microprocessor, but the failure could not
be isolated.
1. Check the management-module event log; if an error
was recorded by the system, see “
POST progress
codes (checkpoints)
” on page
71
.
2. If no entry is found, replace the system-board and
chassis assembly.
A11-01x
A non-critical error has been detected, a CPU
internal error.
1. Check the management-module event log; if an error
was recorded by the system, see “
POST progress
codes (checkpoints)
” on page
71
.
2. If no entry is found, replace the system-board and
chassis assembly.
A11-02x
A non-critical error has been detected, a CPU
internal cache or cache controller error.
1. Check the management-module event log; if an error
was recorded by the system, see “
POST progress
codes (checkpoints)
” on page
71
.
2. If no entry is found, replace the system-board and
chassis assembly.
A11-03x
A non-critical error has been detected, an
external cache parity or multi-bit ECC error.
1. Check the management-module event log; if an error
was recorded by the system, see “
POST progress
codes (checkpoints)
” on page
71
.
2. If no entry is found, see “
Solving undetermined
problems
” on page
194
.
A11-05x
A non-critical error has been detected, a
system bus time-out error.
1. Check the management-module event log; if an error
was recorded by the system, see “
POST progress
codes (checkpoints)
” on page
71
.
2. If no entry is found, replace the system-board and
chassis assembly.
A11-06x
A non-critical error has been detected, a
time-out error waiting for an I/O device.
Check the management-module event log for an
entry around this time. If no entry is found, replace
the system-board and chassis assembly.
A11-50x
Recoverable errors on resource indicate a
trend toward an unrecoverable error.
However, the resource could not be
deconfigured and is still in use.
The system is operating with the potential for
an unrecoverable error.
1. If repair is not immediately available, reboot and the
resource will be deconfigured; operations can
continue in a degraded mode.
2. Check the management-module event log for an entry
around this time. If no entry is found, replace the
system-board and chassis assembly.
A11-510
Resource has been deconfigured and is no
longer in use due to a trend toward an
unrecoverable error.
1. Schedule maintenance; the system is operating in a
degraded mode.
2. Check the management-module event log for an entry
around this time. If no entry is found, replace the
system-board and chassis assembly.
A11-540
Recoverable errors on resource indicate a
trend toward an unrecoverable error.
However, the resource could not be
deconfigured and is still in use. The system is
operating with the potential for an
unrecoverable error.
1. If repair is not immediately available, reboot and the
resource will be deconfigured; operations can
continue in a degraded mode.
2. Check the management-module event log for an entry
around this time. If no entry is found, replace the
system-board and chassis assembly.
A11-550
Recoverable errors on resource indicate a
trend toward an unrecoverable error.
However, the resource could not be
deconfigured and is still in use. The system is
operating with the potential for an
unrecoverable error.
1. If repair is not immediately available, reboot and the
resource will be deconfigured; operations can
continue in a degraded mode.
2. Check the management-module event log for an entry
around this time. If no entry is found, replace the
system-board and chassis assembly.
A12-00x
A non-critical error has been detected. Error
log analysis indicates an error detected by
the memory controller, but the failure could
not be isolated.
1. Check the management-module event log; if an error
was recorded by the system, see “
POST progress
codes (checkpoints)
” on page
71
.
2. If no entry is found, replace the system-board and
chassis assembly.
Содержание Escala BL460
Страница 1: ...Escala BL460 Problem Determination and Service Guide ESCALA Blade REFERENCE 86 A7 81FB 00...
Страница 2: ......
Страница 10: ......
Страница 11: ...Preface vii Safety...
Страница 13: ...Preface ix...
Страница 14: ...x Escala BL460 Problem Determination and Service Guide...
Страница 15: ...Preface xi...
Страница 16: ...xii Escala BL460 Problem Determination and Service Guide...
Страница 17: ...Preface xiii...
Страница 19: ...Preface xv Guidelines for servicing electrical equipment...
Страница 20: ......
Страница 26: ...6 Escala BL460 Problem Determination and Service Guide Figure 1 1 DIMM connectors...
Страница 33: ...Chapter 1 Introduction 13 Figure 1 4 shows individual DIMM connectors Figure 1 4 DIMM connectors...
Страница 220: ...200 Escala BL460 Problem Determination and Service Guide...
Страница 260: ...240 Escala BL460 Problem Determination and Service Guide...
Страница 265: ......
Страница 266: ...BULL CEDOC 357 AVENUE PATTON B P 20845 49008 ANGERS CEDEX 01 FRANCE REFERENCE 86 A7 81FB 00...