Follow the suggested actions in the order in which they are listed in the Action column until the problem
is solved. If an action solves the problem, then you can stop performing the remaining actions.
See
Chapter 3
, “
Parts listing
,” on page
197
to determine which components are CRUs and which
components are FRUs.
B700 xxxx
Error codes
Description
Action
5302
An unsupported Preferred Operating
System was detected.
The Preferred Operating System specified
is not supported. The IPL will not continue.
Work with Bull support to select a supported Preferred
Operating System; then, re-IPL the system.
5303
An unsupported Preferred Operating
System was detected.
The Preferred Operating System specified
is not supported. The IPL will not continue.
Work with Bull support to select a supported Preferred
Operating System; then, re-IPL the system.
5400
System firmware detected a problem with
a processor.
Replace the system-board and chassis assembly, as
described in “
Replacing the Tier 2 system-board and chassis
assembly
” on page
229
.
5442
System firmware detected an error.
Replace the system-board and chassis assembly, as
described in “
Replacing the Tier 2 system-board and chassis
assembly
” on page
229
.
54DD
Informational system log entry only.
No corrective action is required.
5600
Informational system log entry only.
No corrective action is required.
5601
System firmware failure. There was a
problem initializing, reading, or using
system location codes.
Go to “
Firmware problem isolation
” on page
185
.
6900
PCI host bridge failure
1. Replace the system-board and chassis assembly, as
described in “
Replacing the Tier 2 system-board and
chassis assembly
” on page
229
.
2. If the problem persists, use the “
PCI expansion card
(PIOCARD) problem isolation procedure
” on page
164
to
determine the failing component.
6906
System bus error
Replace the system-board and chassis assembly, as
described in “
Replacing the Tier 2 system-board and chassis
assembly
” on page
229
.
6907
System bus error
1. Replace the system-board and chassis assembly, as
described in “
Replacing the Tier 2 system-board and chassis
assembly
” on page
229
.
2. Go to “
Firmware problem isolation
” on page
185
.
6908
System bus error
Replace the system-board and chassis assembly, as
described in “
Replacing the Tier 2 system-board and chassis
assembly
” on page
229
.
6909
System bus error
1. Replace the system-board and chassis assembly, as
described in “
Replacing the Tier 2 system-board and
chassis assembly
” on page
229
.
2. Go to “
Firmware problem isolation
” on page
185
.
6944
Informational system log entry only.
No corrective action is required.
6950
A platform dump has occurred.
1. Collect the platform dump information.
2. Go to “
Firmware problem isolation
” on page
185
.
6951
An error occurred because a partition
needed more NVRAM than was
available.
Use the Integrated Virtualization Manager (IVM) to delete
one or more partitions.
6952
Informational system log entry only.
No corrective action is required.
6953
PHYP NVRAM is unavailable after a
service processor reset and reload.
Go to “
Firmware problem isolation
” on page
185
.
6954
Informational system log entry only.
No corrective action is required.
6955
Informational system log entry only.
No corrective action is required.
6956
An NVRAM failure was detected.
Go to “
Firmware problem isolation
” on page
185
.
Содержание Escala BL460
Страница 1: ...Escala BL460 Problem Determination and Service Guide ESCALA Blade REFERENCE 86 A7 81FB 00...
Страница 2: ......
Страница 10: ......
Страница 11: ...Preface vii Safety...
Страница 13: ...Preface ix...
Страница 14: ...x Escala BL460 Problem Determination and Service Guide...
Страница 15: ...Preface xi...
Страница 16: ...xii Escala BL460 Problem Determination and Service Guide...
Страница 17: ...Preface xiii...
Страница 19: ...Preface xv Guidelines for servicing electrical equipment...
Страница 20: ......
Страница 26: ...6 Escala BL460 Problem Determination and Service Guide Figure 1 1 DIMM connectors...
Страница 33: ...Chapter 1 Introduction 13 Figure 1 4 shows individual DIMM connectors Figure 1 4 DIMM connectors...
Страница 220: ...200 Escala BL460 Problem Determination and Service Guide...
Страница 260: ...240 Escala BL460 Problem Determination and Service Guide...
Страница 265: ......
Страница 266: ...BULL CEDOC 357 AVENUE PATTON B P 20845 49008 ANGERS CEDEX 01 FRANCE REFERENCE 86 A7 81FB 00...