Chapter 2. Diagnostics
35
•
Follow the suggested actions in the order in which they are listed in the Action column until the problem is
solved. If an action solves the problem, then you can stop performing the remaining actions.
•
See
Chapter 3
, “
Parts listing
,” on page
197
to determine which components are CRUs and which
components are FRUs.
B200 xxxx
Error codes
Description Action
5114
A problem occurred during the startup of a
partition. There is not enough space to
contain the partition main storage dump.
The startup will not continue.
Go to “
Firmware problem isolation
” on page
185
.
5115
A problem occurred during the startup of a
partition. There was an error reading the
partition main storage dump from the
partition load source into main storage. The
startup will attempt to continue.
If the startup does not continue, look for and resolve other
errors.
5117
A problem occurred during the startup of a
partition. A partition main storage dump
has occurred but cannot be written to the
load source device because a valid dump
already exists.
Use the Main Storage Dump Manager to rename or copy
the current main storage dump.
5121
A problem occurred during the startup of a
partition. There was an error writing the
partition main storage dump to the partition
load source. The startup will not continue.
Look for related errors in the Product Activity Log and fix
any problems found. Use virtual control panel function 34 to
retry the current Main Store Dump startup while the partition
is still in the failed state.
5122
Informational system log entry only.
No corrective action is required.
5123
Informational system log entry only.
No corrective action is required.
5135
A problem occurred during the startup of a
partition. There was an error writing the
partition main storage dump to the partition
load source. The main store dump startup
will continue.
Look for other errors and resolve them.
5137
A problem occurred during the startup of a
partition. There was an error writing the
partition main storage dump to the partition
load source. The main store dump startup
will continue.
Look for other errors and resolve them.
5145
A problem occurred during the startup of a
partition. There was an error writing the
partition main storage dump to the partition
load source. The main store dump startup
will continue.
Look for other errors and resolve them.
5148
A problem occurred during the startup of a
partition. An error occurred while doing a
main storage dump that would have
caused another main storage dump. The
startup will not continue.
Go to “
Firmware problem isolation
” on page
185
.
5149
A problem occurred during the startup of a
partition while doing a Firmware Assisted
Dump that would have caused another
Firmware Assisted Dump.
Check for server firmware updates; then, install the updates
if available.
514A
A Firmware Assisted Dump did not
complete due to a copy error.
Check for server firmware updates; then, install the updates
if available.
542A
A Firmware Assisted Dump did not
complete due to a read error.
Check for server firmware updates; then, install the updates
if available.
542B
A Firmware Assisted Dump did not
complete due to a copy error.
Check for server firmware updates; then, install the updates
if available.
543A
A Firmware Assisted Dump did not
complete due to a copy error.
Check for server firmware updates; then, install the updates
if available.
543B
A Firmware Assisted Dump did not
complete due to a copy error.
Check for server firmware updates; then, install the updates
if available.
543C
Informational system log entry only.
No corrective action is required.
Содержание Escala BL460
Страница 1: ...Escala BL460 Problem Determination and Service Guide ESCALA Blade REFERENCE 86 A7 81FB 00...
Страница 2: ......
Страница 10: ......
Страница 11: ...Preface vii Safety...
Страница 13: ...Preface ix...
Страница 14: ...x Escala BL460 Problem Determination and Service Guide...
Страница 15: ...Preface xi...
Страница 16: ...xii Escala BL460 Problem Determination and Service Guide...
Страница 17: ...Preface xiii...
Страница 19: ...Preface xv Guidelines for servicing electrical equipment...
Страница 20: ......
Страница 26: ...6 Escala BL460 Problem Determination and Service Guide Figure 1 1 DIMM connectors...
Страница 33: ...Chapter 1 Introduction 13 Figure 1 4 shows individual DIMM connectors Figure 1 4 DIMM connectors...
Страница 220: ...200 Escala BL460 Problem Determination and Service Guide...
Страница 260: ...240 Escala BL460 Problem Determination and Service Guide...
Страница 265: ......
Страница 266: ...BULL CEDOC 357 AVENUE PATTON B P 20845 49008 ANGERS CEDEX 01 FRANCE REFERENCE 86 A7 81FB 00...