Chapter 2. Diagnostics
29
•
Follow the suggested actions in the order in which they are listed in the Action column until the problem is
solved. If an action solves the problem, then you can stop performing the remaining actions.
•
See
Chapter 3
, “
Parts listing
,” on page
197
to determine which components are CRUs and which
components are FRUs.
Attention
code
Description
Action
AA060007
A keyboard was not found.
Verify that a keyboard is attached to the USB port that is assigned to
the partition.
AA06000B
The system or partition was not
able to find an operating system
on any of the devices in the boot
list.
1. Use the SMS menus to modify the boot list so that it includes
devices that have a known-good operating system and restart the
blade server.
2. If the problem remains, go to “
Boot problem resolution
” on page
156
.
AA06000C
The media in a device in the
boot list was not bootable.
1. Replace the media in the device with known-good media or
modify the boot list to boot from another bootable device.
2. If the problem remains, go to “
Boot problem resolution
” on page
156
.
AA06000D
The media in the device in the
bootlist was not found under the
I/O adapter specified by the
bootlist.
1. Verify that the media from which you are trying to boot is bootable
or modify the boot list to boot from another bootable device.
2. If the problem remains, go to “
Boot problem resolution
” on page
156
.
AA06000E
The adapter specified in the
boot list is not present or is not
functioning.
•
For an AIX operating system:
1. Try booting the blade server from another bootable device;
then, run AIX online diagnostics against the failing adapter.
2. If AIX cannot be booted from another device, boot the blade
server using the stand-alone
Diagnostics
CD or a NIM server;
then, run diagnostics against the failing adapter.
•
For a Linux operating system, boot the blade server using the
stand-alone
Diagnostics
CD or a NIM server; then, run
diagnostics against the failing adapter.
AA060011
The firmware did not find an
operating system image and at
least one hard disk in the boot
list was not detected by the
firmware. The firmware is
retrying the entries in the boot
list.
This might occur if a disk enclosure that contains the boot disk is not
fully initialized or if the boot disk belongs to another partition.
Verify that:
•
The boot disk belongs to the partition from which you are trying to
boot.
•
The boot list in the SMS menus is correct.
AA130013
Bootable media is missing from
a USB CD-ROM
Verify that a bootable CD is properly inserted in the CD or DVD drive
and retry the boot operation.
AA130014
The media in a USB CD-ROM
has changed.
1. Retry the operation.
2. Check for server firmware updates; then, install the updates if
available and retry the operation.
AA170210
Setenv/$setenv parameter error
- the name contains a null
character.
1. Go to “
Checkout procedure
” on page
148
.
2. Replace the system-board and chassis assembly, as described in
“
Replacing the Tier 2 system-board and chassis assembly
”
on page
229
.
AA170211
Setenv/$setenv parameter error
- the value contains a null
character.
1. Go to “
Checkout
procedure
” on page
148
.
2. Replace the system-board and chassis assembly, as described in
“
Replacing the Tier 2 system-board and chassis assembly
”
on page
229
.
AA190001
The hypervisor function to get or
set the time-of-day clock reported
an error.
1. Use the operating system to set the system clock.
2. If the problem persists, check for server firmware updates.
3. Install any available updates and retry the operation.
AA260001
Enter the Type Model Number
(Must be 8 characters)
Enter the machine type and model of the blade server at the prompt.
AA260002
Enter the Serial Number (Must
be 7 characters)
Enter the serial number of the blade server at the prompt.
Содержание Escala BL460
Страница 1: ...Escala BL460 Problem Determination and Service Guide ESCALA Blade REFERENCE 86 A7 81FB 00...
Страница 2: ......
Страница 10: ......
Страница 11: ...Preface vii Safety...
Страница 13: ...Preface ix...
Страница 14: ...x Escala BL460 Problem Determination and Service Guide...
Страница 15: ...Preface xi...
Страница 16: ...xii Escala BL460 Problem Determination and Service Guide...
Страница 17: ...Preface xiii...
Страница 19: ...Preface xv Guidelines for servicing electrical equipment...
Страница 20: ......
Страница 26: ...6 Escala BL460 Problem Determination and Service Guide Figure 1 1 DIMM connectors...
Страница 33: ...Chapter 1 Introduction 13 Figure 1 4 shows individual DIMM connectors Figure 1 4 DIMM connectors...
Страница 220: ...200 Escala BL460 Problem Determination and Service Guide...
Страница 260: ...240 Escala BL460 Problem Determination and Service Guide...
Страница 265: ......