Chapter 2. Diagnostics
123
SRN FFC
Description and Action
256D-601
256D
Error log analysis indicates adapter.
1. Check the management-module event log. If an error was recorded by the system, see
“
POST progress codes (checkpoints)
” on page
71
.
2. Replace any parts reported by the diagnostic program.
3. Replace the system-board and chassis assembly.
256D-602
256D
Error log analysis indicates an error attention condition.
1. Check the management-module event log. If an error was recorded by the system, see
“
POST progress codes (checkpoints)
” on page
71
.
2. Replace any parts reported by the diagnostic program.
3. Replace the system-board and chassis assembly.
256D-603
256D
Error Log Analysis indicates that the microcode could not be loaded on the adapter.
1. Check the management-module event log. If an error was recorded by the system, see
“
POST progress codes (checkpoints)
” on page
71
.
2. Replace any parts reported by the diagnostic program.
3. Replace the system-board and chassis assembly.
256D-604
256D 210
Error Log Analysis indicates a permanent adapter failure.
1. Check the management-module event log. If an error was recorded by the system, see
“
POST progress codes (checkpoints)
” on page
71
.
2. Replace any parts reported by the diagnostic program.
3. Replace the system-board and chassis assembly.
256D-605 256D
Error Log Analysis indicates a permanent adapter failure.
1. Check the management-module event log. If an error was recorded by the system, see
“
POST progress codes (checkpoints)
” on page
71
.
2. Replace any parts reported by the diagnostic program.
3. Replace the system-board and chassis assembly.
256D-606
256D
Error Log Analysis indicates adapter failure.
1. Check the management-module event log. If an error was recorded by the system, see
“
POST progress codes (checkpoints)
” on page
71
.
2. Replace any parts reported by the diagnostic program.
3. Replace the system-board and chassis assembly.
256D-701
256D 221
Error Log Analysis indicates permanent adapter failure.
1. Check the management-module event log. If an error was recorded by the system, see
“
POST progress codes (checkpoints)
” on page
71
.
2. Replace any parts reported by the diagnostic program.
3. Replace the system-board and chassis assembly.
256D-702
256D 221
Error Log Analysis indicates permanent adapter failure is reported on the other port of this
adapter.
1. Check the management-module event log. If an error was recorded by the system, see
“
POST progress codes (checkpoints)
” on page
71
.
2. Replace any parts reported by the diagnostic program.
3. Replace the system-board and chassis assembly.
25C4-xxx
25C4
Generic reference for Broadcom adapter. Go to “
Performing the checkout procedure
” on
page
149
.
25C4-201
25C4
Configuration error. Go to “
Performing the checkout procedure
” on page
149
.
25C4-701
25C4
Permanent adapter failure. Go to “
Performing the checkout procedure
” on page
149
.
25C4-601
25C4
Download firmware error. Go to “
Performing the checkout procedure
” on page
149
.
25C4-602
25C4
EEPROM read error. Go to “
Performing the checkout procedure
” on page
149
.
2604-xxx 2604
Generic reference for 4Gb Fibre Channel Adapter card. Go to “
Performing the checkout
procedure
” on page
149
.
2604-102 2604
Reset Test failure for the Fibre Channel adapter card. Replace the 4Gb Fibre Channel
Adapter card.
Содержание Escala BL460
Страница 1: ...Escala BL460 Problem Determination and Service Guide ESCALA Blade REFERENCE 86 A7 81FB 00...
Страница 2: ......
Страница 10: ......
Страница 11: ...Preface vii Safety...
Страница 13: ...Preface ix...
Страница 14: ...x Escala BL460 Problem Determination and Service Guide...
Страница 15: ...Preface xi...
Страница 16: ...xii Escala BL460 Problem Determination and Service Guide...
Страница 17: ...Preface xiii...
Страница 19: ...Preface xv Guidelines for servicing electrical equipment...
Страница 20: ......
Страница 26: ...6 Escala BL460 Problem Determination and Service Guide Figure 1 1 DIMM connectors...
Страница 33: ...Chapter 1 Introduction 13 Figure 1 4 shows individual DIMM connectors Figure 1 4 DIMM connectors...
Страница 220: ...200 Escala BL460 Problem Determination and Service Guide...
Страница 260: ...240 Escala BL460 Problem Determination and Service Guide...
Страница 265: ......
Страница 266: ...BULL CEDOC 357 AVENUE PATTON B P 20845 49008 ANGERS CEDEX 01 FRANCE REFERENCE 86 A7 81FB 00...