136
Escala BL460 -
Problem Determination and Service Guide
SRN Description
FRU/action
A13-09x
A non-critical error has been detected, a
system bus data parity error.
1. Check the management-module event log; if an error
was recorded by the system, see “
POST progress
codes (checkpoints)
” on page
71
.
2. If no entry is found, replace the system-board and
chassis assembly.
A13-11x
A non-critical error has been detected, a
system bus time-out error
1. Check the management-module event log; if an error
was recorded by the system, see “
POST progress
codes (checkpoints)
” on page
71
.
2. If no entry is found, replace the system-board and
chassis assembly.
A13-12x
A non-critical error has been detected, an
error on system bus.
1. Check the management-module event log; if an error
was recorded by the system, see “
POST progress
codes (checkpoints)
” on page
71
.
2. If no entry is found, replace the system-board and
chassis assembly.
A13-13x
A non-critical error has been detected, an
I/O expansion bus parity error.
1. Check the management-module event log; if an error
was recorded by the system, see “
POST progress
codes (checkpoints)
” on page
71
.
2. If no entry is found, replace the system-board and
chassis assembly.
A13-14x
A non-critical error has been detected, an
I/O expansion bus time-out error.
1. Check the management-module event log; if an error
was recorded by the system, see “
POST progress
codes (checkpoints)
” on page
71
.
2. If no entry is found, replace the system-board and
chassis assembly.
A13-15x
A non-critical error has been detected, an
I/O expansion bus connection failure.
1. Check the management-module event log; if an error
was recorded by the system, see “
POST progress
codes (checkpoints)
” on page
71
.
2. If no entry is found, replace the system-board and
chassis assembly.
A13-16x
A non-critical error has been detected, an
I/O expansion unit not in an operating state.
1. Check the management-module event log; if an error
was recorded by the system, see “
POST progress
codes (checkpoints)
” on page
71
.
2. If no entry is found, replace the system-board and
chassis assembly.
A13-50x
Recoverable errors on resource indicate a
trend toward an unrecoverable error.
However, the resource could not be
deconfigured and is still in use. The system is
operating with the potential for an
unrecoverable error.
1. If repair is not immediately available, reboot and the
resource will be deconfigured; operations can
continue in a degraded mode.
2. Check the management-module event log for an entry
around this time. If no entry is found, replace the
system-board and chassis assembly.
A15-01x
Sensor indicates a fan is turning too slowly.
1. Check the management-module event log; if an error
was recorded by the system, see “
POST progress
codes (checkpoints)
” on page
71
.
2. If no entry is found, replace the system-board and
chassis assembly.
A15-03x
Sensor indicates a voltage outside normal
range.
1. Check the management-module event log; if an error
was recorded by the system, see “
POST progress
codes (checkpoints)
” on page
71
.
2. If no entry is found, replace the system-board and
chassis assembly.
A15-05x
Sensor indicates an abnormally high internal
temperature.
1. Make sure that:
a. The room ambient temperature is within the
system operating environment.
b. There is unrestricted air flow around the system.
c. All system covers are closed.
d. There are no fan failures
2. Check the management-module event log; if an error
was recorded by the system, see “
POST progress
codes (checkpoints)
” on page
71
.
3. If no entry is found, replace the system-board and
chassis assembly.
Содержание Escala BL460
Страница 1: ...Escala BL460 Problem Determination and Service Guide ESCALA Blade REFERENCE 86 A7 81FB 00...
Страница 2: ......
Страница 10: ......
Страница 11: ...Preface vii Safety...
Страница 13: ...Preface ix...
Страница 14: ...x Escala BL460 Problem Determination and Service Guide...
Страница 15: ...Preface xi...
Страница 16: ...xii Escala BL460 Problem Determination and Service Guide...
Страница 17: ...Preface xiii...
Страница 19: ...Preface xv Guidelines for servicing electrical equipment...
Страница 20: ......
Страница 26: ...6 Escala BL460 Problem Determination and Service Guide Figure 1 1 DIMM connectors...
Страница 33: ...Chapter 1 Introduction 13 Figure 1 4 shows individual DIMM connectors Figure 1 4 DIMM connectors...
Страница 220: ...200 Escala BL460 Problem Determination and Service Guide...
Страница 260: ...240 Escala BL460 Problem Determination and Service Guide...
Страница 265: ......
Страница 266: ...BULL CEDOC 357 AVENUE PATTON B P 20845 49008 ANGERS CEDEX 01 FRANCE REFERENCE 86 A7 81FB 00...