Chapter 2. Diagnostics
177
•
Follow the suggested actions in the order in which they are listed in the Action column until the problem is solved.
•
See
Chapter 3
, “
Parts listing
,” on page
197
to determine which components are CRUs and which components are
FRUs.
•
If an action step is preceded by “(Trained service technician only),” that step must be performed only by a trained
service technician.
Isolation
Procedure Code
Symptom Action
FSPSP34
The memory cards are
plugged in an invalid
configuration and
cannot be used by the
system.
Install a DIMM for each of the dual processors on the ESCALA BL460 blade
server. Install the first pair in DIMM connectors 2 and 4.
Look for the following error codes in order. Follow the procedure for the first
code you find.
SRC B1xx C02A A memory card is missing from the system.
The additional parts in the CRU callout list include all memory cards in the
group with the missing card. To correct the error, visually check the system
to determine which card is missing, and add the card.
SRC B1xx C029 A memory card is a different type than the other memory
cards in the same group.
The additional parts in the CRU callout list include all memory cards in the
group that contain the error. To correct the error, exchange the
memory cards of the incorrect type with those of the correct type.
SRC B1xx C02B A group of memory cards are missing and are required
so that other memory cards on the board can be configured.
The additional parts in the CRU callout list include all the missing memory
cards in the group. To correct the error, add or move the memory cards to
the correct locations.
SRC B1xx C036 A memory card is not supported in this system.
The additional parts in the CRU callout list include all memory cards in the
group that contain the unsupported cards. To correct the error, remove the
unsupported cards from the system or replace them with the correct type.
FSPSP35
The system has
detected a problem
with a memory
controller.
Enable redundant utilization by performing the following procedure:
1. Power off the blade server, as described in “
Turning off the blade server
”
on page
11
.
2. Remove the blade server from the Bull Blade Chassis - Enterprise and
reinsert the blade server.
3. Power on the blade server, as described in “
Turning on the blade
server
” on page
10
.
FSPSP38
The system has
detected an error
within the JTAG path.
Replace the CRU that is called out before this FSPSP38 call. If the CRU that
you replace does not correct the problem, call Bull Support.
FSPSP42
An error
communicating
between two system
processors was
detected.
Contact Bull Support.
FSPSP45
The system has
detected an error
within the FSI path.
Replace the system board and chassis assembly, as described in
“
Replacing the Tier 2 system-board and chassis assembly
” on page
229
.
Содержание Escala BL460
Страница 1: ...Escala BL460 Problem Determination and Service Guide ESCALA Blade REFERENCE 86 A7 81FB 00...
Страница 2: ......
Страница 10: ......
Страница 11: ...Preface vii Safety...
Страница 13: ...Preface ix...
Страница 14: ...x Escala BL460 Problem Determination and Service Guide...
Страница 15: ...Preface xi...
Страница 16: ...xii Escala BL460 Problem Determination and Service Guide...
Страница 17: ...Preface xiii...
Страница 19: ...Preface xv Guidelines for servicing electrical equipment...
Страница 20: ......
Страница 26: ...6 Escala BL460 Problem Determination and Service Guide Figure 1 1 DIMM connectors...
Страница 33: ...Chapter 1 Introduction 13 Figure 1 4 shows individual DIMM connectors Figure 1 4 DIMM connectors...
Страница 220: ...200 Escala BL460 Problem Determination and Service Guide...
Страница 260: ...240 Escala BL460 Problem Determination and Service Guide...
Страница 265: ......
Страница 266: ...BULL CEDOC 357 AVENUE PATTON B P 20845 49008 ANGERS CEDEX 01 FRANCE REFERENCE 86 A7 81FB 00...