Chapter 2. Diagnostics
39
Table 2-12. B700xxxx Licensed internal code SRCs
Follow the suggested actions in the order in which they are listed in the Action column until the problem
is solved. If an action solves the problem, then you can stop performing the remaining actions.
See
Chapter 3
, “
Parts listing
,” on page
197
to determine which components are CRUs and which
components are FRUs.
B700 xxxx
Error codes
Description
Action
0102
System firmware detected an error. A
machine check occurred during startup.
1. Collect the event log information.
2. Go to “
Firmware problem isolation
” on page
185
.
0103
System firmware detected a failure
1. Collect the event log information.
2. Collect the platform dump information.
3. Go to “
Firmware problem isolation
” on page
185
.
0104
System firmware failure. Machine check,
undefined error occurred.
1. Check for server firmware updates.
2. Update the firmware.
0105
System firmware detected an error.
More than one request to terminate the
system was issued.
Go to “
Firmware problem isolation
” on page
185
.
0106
System firmware failure.
1. Collect the event log information.
2. Collect the platform dump information.
3. Go to “
Firmware problem isolation
” on page
185
.
0107
System firmware failure. The system
detected an unrecoverable machine
check condition.
1. Collect the event log information.
2. Collect the platform dump information.
3. Go to “
Firmware problem isolation
” on page
185
.
0200
System firmware has experienced a low
storage condition
No immediate action is necessary.
Continue running the system normally. At the earliest
convenient time or service window, work with Bull Support
to collect a platform dump and restart the system; then, go to
“
Firmware problem isolation
” on page
185
.
0201
System firmware detected an error
No immediate action is necessary.
Continue running the system normally. At the earliest
convenient time or service window, work with Bull Support
to collect a platform dump and restart the system; then, go to
“
Firmware problem isolation
” on page
185
.
0302
System firmware failure
1. Collect the platform dump information.
2. Go to “
Firmware problem isolation
” on page
185
.
0441
Service processor failure. The platform
encountered an error early in the startup
or termination process.
Replace the system-board and chassis assembly, as
described in “
Replacing the Tier 2 system-board and chassis
assembly
” on page
229
.
0443
Service processor failure.
Replace the system-board and chassis assembly, as
described in “
Replacing the Tier 2 system-board and chassis
assembly
” on page
229
.
0601
Informational system log entry only.
No corrective action is required.
Note: This code and associated data can be used to
determine why the time of day for a partition was lost.
0602
System firmware detected an error
condition.
1. Collect the event log information.
2. Go to “
Firmware problem isolation
” on page
185
.
0611
There is a problem with the system
hardware clock; the clock time is invalid.
Use the operating system to set the system clock.
0621
Informational system log entry only.
No corrective action is required.
0641
System firmware detected an error.
1. Collect the platform dump information.
2. Go to “
Firmware problem isolation
” on page
185
.
Содержание Escala BL460
Страница 1: ...Escala BL460 Problem Determination and Service Guide ESCALA Blade REFERENCE 86 A7 81FB 00...
Страница 2: ......
Страница 10: ......
Страница 11: ...Preface vii Safety...
Страница 13: ...Preface ix...
Страница 14: ...x Escala BL460 Problem Determination and Service Guide...
Страница 15: ...Preface xi...
Страница 16: ...xii Escala BL460 Problem Determination and Service Guide...
Страница 17: ...Preface xiii...
Страница 19: ...Preface xv Guidelines for servicing electrical equipment...
Страница 20: ......
Страница 26: ...6 Escala BL460 Problem Determination and Service Guide Figure 1 1 DIMM connectors...
Страница 33: ...Chapter 1 Introduction 13 Figure 1 4 shows individual DIMM connectors Figure 1 4 DIMM connectors...
Страница 220: ...200 Escala BL460 Problem Determination and Service Guide...
Страница 260: ...240 Escala BL460 Problem Determination and Service Guide...
Страница 265: ......
Страница 266: ...BULL CEDOC 357 AVENUE PATTON B P 20845 49008 ANGERS CEDEX 01 FRANCE REFERENCE 86 A7 81FB 00...