Chapter 2. Diagnostics
43
Follow the suggested actions in the order in which they are listed in the Action column until the problem
is solved. If an action solves the problem, then you can stop performing the remaining actions.
See
Chapter 3
, “
Parts listing
,” on page
197
to determine which components are CRUs and which
components are FRUs.
B700 xxxx
Error codes
Description
Action
6965
Informational system log entry only.
No corrective action is required.
6970
PCI host bridge failure
1. Replace the system-board and chassis assembly, as
described in “
Replacing the Tier 2 system-board and
chassis assembly
” on page
229
.
2. If the problem persists, use the “
PCI expansion card
(PIOCARD) problem isolation procedure
” on page
164
to determine the failing component.
6971
PCI bus failure
1. Use the “
PCI expansion card (PIOCARD) problem
isolation procedure
” on page
164
to determine the
failing component.
2. If the problem persists, replace the system-board and
chassis assembly, as described in “
Replacing the Tier 2
system-board and chassis assembly
” on page
229
.
6972
System bus error
Replace the system-board and chassis assembly, as
described in “
Replacing the Tier 2 system-board and chassis
assembly
” on page
229
.
6973
System bus error
1. Use the “
PCI expansion card (PIOCARD) problem
isolation procedure
” on page
164
to determine the
failing component.
2. If the problem persists, replace the system-board and
chassis assembly, as described in “
Replacing the Tier 2
system-board and chassis assembly
” on page
229
.
6974
Informational system log entry only.
No corrective action is required.
6978
Informational system log entry only.
No corrective action is required.
6979
Informational system log entry only.
No corrective action is required.
697C
Connection from service processor to
system processor failed.
Replace the system-board and chassis assembly, as
described in “
Replacing the Tier 2 system-board and chassis
assembly
” on page
229
.
6980
Remote I/O (RIO), high-speed link (HSL),
or 12X controller failure
Replace the system-board and chassis assembly, as
described in “
Replacing the Tier 2 system-board and chassis
assembly
” on page
229
.
6981
System bus error.
Replace the system-board and chassis assembly, as
described in “
Replacing the Tier 2 system-board and chassis
assembly
” on page
229
.
6984
Informational system log entry only.
No corrective action is required.
6985
Remote I/O (RIO), high-speed link (HSL),
or 12X loop status message.
Replace the system-board and chassis assembly, as
described in “
Replacing the Tier 2 system-board and chassis
assembly
” on page
229
.
6987
Remote I/O (RIO), high-speed link (HSL),
or 12X connection failure
Replace the system-board and chassis assembly, as
described in “
Replacing the Tier 2 system-board and chassis
assembly
” on page
229
.
6990
Service processor failure.
Replace the system-board and chassis assembly, as
described in “
Replacing the Tier 2 system-board and chassis
assembly
” on page
229
.
6991
System firmware failure
Go to “
Firmware problem isolation
” on page
185
.
6993
Service processor failure
1. Replace the system-board and chassis assembly, as
described in “
Replacing the Tier 2 system-board and
chassis assembly
” on page
229
.
2. Go to “
Firmware problem isolation
” on page
185
.
6994
Service processor failure.
Replace the system-board and chassis assembly, as
described in “
Replacing the Tier 2 system-board and chassis
assembly
” on page
229
.
6995
Informational system log entry only.
No corrective action is required.
69C2
Informational system log entry only.
No corrective action is required.
Содержание Escala BL460
Страница 1: ...Escala BL460 Problem Determination and Service Guide ESCALA Blade REFERENCE 86 A7 81FB 00...
Страница 2: ......
Страница 10: ......
Страница 11: ...Preface vii Safety...
Страница 13: ...Preface ix...
Страница 14: ...x Escala BL460 Problem Determination and Service Guide...
Страница 15: ...Preface xi...
Страница 16: ...xii Escala BL460 Problem Determination and Service Guide...
Страница 17: ...Preface xiii...
Страница 19: ...Preface xv Guidelines for servicing electrical equipment...
Страница 20: ......
Страница 26: ...6 Escala BL460 Problem Determination and Service Guide Figure 1 1 DIMM connectors...
Страница 33: ...Chapter 1 Introduction 13 Figure 1 4 shows individual DIMM connectors Figure 1 4 DIMM connectors...
Страница 220: ...200 Escala BL460 Problem Determination and Service Guide...
Страница 260: ...240 Escala BL460 Problem Determination and Service Guide...
Страница 265: ......
Страница 266: ...BULL CEDOC 357 AVENUE PATTON B P 20845 49008 ANGERS CEDEX 01 FRANCE REFERENCE 86 A7 81FB 00...