180
Escala BL460 -
Problem Determination and Service Guide
•
Follow the suggested actions in the order in which they are listed in the Action column until the problem is solved.
•
See
Chapter 3
, “
Parts listing
,” on page
197
to determine which components are CRUs and which components are
FRUs.
•
If an action step is preceded by “(Trained service technician only),” that step must be performed only by a trained
service technician.
Isolation
Procedure Code
Symptom Action
MEMDIMM
Symbolic CRU
The failing component
is one of the memory
DIMMs.
1. Replace the failing CRU:
DIMM 1 (Px-C1)
P1-C1 is memory module 1
DIMM 2 (Px-C2)
Memory module 2
DIMM 3 (Px-C3)
Memory module 3
DIMM 4 (Px-C4)
Memory module 4
DIMM 5 (Px-C5)
Memory module 5
DIMM 6 (Px-C6)
Memory module 6
DIMM 7 (Px-C7)
Memory module 7
DIMM 8 (Px-C8)
Memory module 8
2. See “
Removing a memory module
” on page
213
for location information
and the removal procedure.
3. Install new memory DIMMs, as described in “
Installing a memory
module
” on page
214
.
See “
Supported DIMMs
” on page
5
for more information.
NO12VDC
Symbolic CRU
Error code 1xxx2647
indicates that the
blade server is
reporting that 12V dc
is not present on the
Bull Blade Chassis -
Enterprise midplane.
1. Check the management-module event log for entries that indicate a
power problem with the Bull Blade Chassis - Enterprise.
2. Resolve any problems.
3. Remove the blade from the Bull Blade Chassis - Enterprise and then
reinsert the blade server.
4. Power on the blade server.
5. Monitor the blade server operation to verify that the problem is solved.
6. If the Chassis is functioning normally, but the 1xxx2647 problem
persists, Replace the system board and chassis assembly, as described in
“
Replacing the Tier 2 system-board and chassis assembly
” on
page
229
.
NODEPL Symbolic
CRU
The failing component
is the node midplane.
Replace the system board and chassis assembly, as described in
“
Replacing the Tier 2 system-board and chassis assembly
” on page
229
.
TOD_BAT
Symbolic CRU
The battery for the
time-of-day battery is
low or failing.
Replace the battery, as described in “
Removing the battery
” on page
224
and “
Installing the battery
” on page
225
.
Содержание Escala BL460
Страница 1: ...Escala BL460 Problem Determination and Service Guide ESCALA Blade REFERENCE 86 A7 81FB 00...
Страница 2: ......
Страница 10: ......
Страница 11: ...Preface vii Safety...
Страница 13: ...Preface ix...
Страница 14: ...x Escala BL460 Problem Determination and Service Guide...
Страница 15: ...Preface xi...
Страница 16: ...xii Escala BL460 Problem Determination and Service Guide...
Страница 17: ...Preface xiii...
Страница 19: ...Preface xv Guidelines for servicing electrical equipment...
Страница 20: ......
Страница 26: ...6 Escala BL460 Problem Determination and Service Guide Figure 1 1 DIMM connectors...
Страница 33: ...Chapter 1 Introduction 13 Figure 1 4 shows individual DIMM connectors Figure 1 4 DIMM connectors...
Страница 220: ...200 Escala BL460 Problem Determination and Service Guide...
Страница 260: ...240 Escala BL460 Problem Determination and Service Guide...
Страница 265: ......
Страница 266: ...BULL CEDOC 357 AVENUE PATTON B P 20845 49008 ANGERS CEDEX 01 FRANCE REFERENCE 86 A7 81FB 00...