Error code
Description
Action
BA012010
Opening the TCP node failed.
1. Reboot the blade server.
2. If the problem persists:
a. Go to “
Checkout procedure
” on page
148
.
b. Replace the system-board and chassis assembly, as
described in “
Replacing the Tier 2 system-board
and chassis assembly
” on page
229
.
BA012011
TCP failed to read from the network
1. Reboot the blade server.
2. If the problem persists:
a. Go to “
Checkout procedure
” on page
148
.
b. Replace the system-board and chassis assembly, as
described in “
Replacing the Tier 2 system-board
and chassis assembly
” on page
229
.
BA012012
TCP failed to write to the network.
1. Reboot the blade server.
2. If the problem persists:
a. Go to “
Checkout procedure
” on page
148
.
b. Replace the system-board and chassis assembly, as
described in “
Replacing the Tier 2 system-board
and chassis assembly
” on page
229
.
BA012013
Closing TCP failed.
1. Reboot the blade server.
2. If the problem persists:
a. Go to “
Checkout procedure
” on page
148
.
b. Replace the system-board and chassis assembly, as
described in “
Replacing the Tier 2 system-board
and chassis assembly
” on page
229
.
BA017020
Failed to open the TFTP package
Verify that the Trivial File Transfer Protocol (TFTP) parameters
are correct.
BA017021
Failed to load the TFTP file
Verify that the TFTP server and network connections are
correct.
BA01B010
Opening the BOOTP node failed.
1. Reboot the blade server.
2. If the problem persists:
a. Go to “
Checkout procedure
” on page
148
.
b. Replace the system-board and chassis assembly, as
described in “
Replacing the Tier 2 system-board
and chassis assembly
” on page
229
.
BA01B011
BOOTP failed to read from the network
Perform the following actions that checkpoint
CA00E174 describes:
1. Verify that:
−
The bootp server is correctly configured;
then, retry the operation.
−
The network connections are correct;
then, retry the operation.
2. If the problem persists:
a. Go to “
Checkout procedure
” on page
148
.
b. Replace the system-board and chassis assembly, as
described in “
Replacing the Tier 2 system-board
and chassis assembly
” on page
229
.
Содержание Escala BL460
Страница 1: ...Escala BL460 Problem Determination and Service Guide ESCALA Blade REFERENCE 86 A7 81FB 00...
Страница 2: ......
Страница 10: ......
Страница 11: ...Preface vii Safety...
Страница 13: ...Preface ix...
Страница 14: ...x Escala BL460 Problem Determination and Service Guide...
Страница 15: ...Preface xi...
Страница 16: ...xii Escala BL460 Problem Determination and Service Guide...
Страница 17: ...Preface xiii...
Страница 19: ...Preface xv Guidelines for servicing electrical equipment...
Страница 20: ......
Страница 26: ...6 Escala BL460 Problem Determination and Service Guide Figure 1 1 DIMM connectors...
Страница 33: ...Chapter 1 Introduction 13 Figure 1 4 shows individual DIMM connectors Figure 1 4 DIMM connectors...
Страница 220: ...200 Escala BL460 Problem Determination and Service Guide...
Страница 260: ...240 Escala BL460 Problem Determination and Service Guide...
Страница 265: ......
Страница 266: ...BULL CEDOC 357 AVENUE PATTON B P 20845 49008 ANGERS CEDEX 01 FRANCE REFERENCE 86 A7 81FB 00...