Chapter 3: Configuring Your Library
Working With Data Path Conditioning
Quantum Scalar i6000 User’s Guide
251
4
Click a blade to highlight it, and then click
Configure
. The
Datapath Conditioning Setting
dialog box appears.
5
In the
Level
area, select the appropriate level. The default level is
Interface Test
. To enable data path monitoring tickets, set the level
to
Device Datapath Test
.
The following table describes the functionality for each data path
monitoring level.
Level Name
Functionality Description
Interface Test
Performs tests to verify that Fibre Channel controllers on I/O blades are responsive
to commands.
Device Datapath
Test
Performs tests at the Interface Test level, and also performs a device inquiry on
each target device.