Chapter 15: Maintaining Your Library
Maintenance Actions
Quantum Scalar i6000 User’s Guide
677
Cycling Library Power
If library firmware seems to be at fault, or the robot will not move, or a
circuit board has gone down, try recycling power to the library. Cycling
library power involves shutting down the library, powering it off, and
then powering it on. For more information, see
Caution: Do not cycle library power for a drive problem. Use
Tools
>
Drives to power cycle the individual drive.
Removing Lodged
Cartridges
It is very unlikely that a cartridge will become lodged in the robot. If this
happens, contact technical support. It also is very unlikely that a
cartridge will become lodged in a drive. If this happens, it is not difficult
to remove it.
Removing a Cartridge From a Drive
Required tools:
None
1
On the operator panel, press the
Robotics Enabled
button to turn
off power to the picker and return it to the home position. The
power is on to all other components.
2
Open the access door. Aisle power is disabled.
3
On the drive, press the
Eject
button, and then remove the cartridge.
4
Close the access door. The power is on.
5
On the operator panel, press the
Robotics Enabled
button to
enable the picker.
Summary of Contents for Scalar i6000
Page 1: ...User s Guide Scalar i6000 6 66879 15 Rev B...
Page 276: ...Chapter 3 Configuring Your Library Working with Towers 258 Quantum Scalar i6000 User s Guide...
Page 344: ...Chapter 8 Encryption Key Management Using SKM 326 Quantum Scalar i6000 User s Guide...
Page 444: ...Chapter 11 Configuring Access to StorNext 426 Quantum Scalar i6000 User s Guide...
Page 450: ...Chapter 12 Partition Utilization Reporting 432 Quantum Scalar i6000 User s Guide...
Page 574: ...Chapter 15 Maintaining Your Library Maintenance Actions 556 Quantum Scalar i6000 User s Guide...
Page 730: ...Appendix A Frequently Asked Questions 684 Quantum Scalar i6000 User s Guide...