Chapter 3: Configuring Your Library
Setting Up the Network Configuration
172
Quantum Scalar i6000 User’s Guide
1
From the local operator panel only, select
Setup > Network
Configuration
>
Internal IP
. The
Change Internal IP
dialog box
appears.
By default, the internal IP subnet address that is automatically
selected on the
Change Internal IP
dialog box is not the one to
which your internal network is currently set. For example, the
current internal network IP setting is 192.19.x.x,. The drop-down
menu has multiple subnet options from 192.19.x.x to 10.90.x.x.
2
To accept the automatic internal IP setting, click
OK
. The following
warning message appears.
Caution:
Setting the internal IP network to be on the same
subnet that the external IP network is on causes library
failure and results in the management interface (the
MCB) becoming unusable. For example, if you set
10.10.X.X as the internal IP network and your external
IP network is also 10.10.X.X, a conflict occurs. If you
are unsure about whether the change is appropriate,
select
No
.
3
If you are sure that you want to make the change, select
Yes
.
4
After the library processes the request successfully, a message
appears that asks you whether you want to shut down the library.
You must shut down and restart the library in order for the changes
to take effect.
Summary of Contents for Scalar i6000
Page 1: ...User s Guide Scalar i6000 6 66879 15 Rev B...
Page 276: ...Chapter 3 Configuring Your Library Working with Towers 258 Quantum Scalar i6000 User s Guide...
Page 344: ...Chapter 8 Encryption Key Management Using SKM 326 Quantum Scalar i6000 User s Guide...
Page 444: ...Chapter 11 Configuring Access to StorNext 426 Quantum Scalar i6000 User s Guide...
Page 450: ...Chapter 12 Partition Utilization Reporting 432 Quantum Scalar i6000 User s Guide...
Page 574: ...Chapter 15 Maintaining Your Library Maintenance Actions 556 Quantum Scalar i6000 User s Guide...
Page 730: ...Appendix A Frequently Asked Questions 684 Quantum Scalar i6000 User s Guide...