Chapter 3: Configuring Your Library
About the Configuration Record
252
Quantum Scalar i6000 User’s Guide
6
In the
Enter new Interval
text box, type the amount of time that
should elapse between automatic monitoring checks. The interval
can range from 1 to 2,880 minutes (48 hours). The default interval is
60 minutes.
Note:
The data path from I/O blade to the drive must experience
problems for two period intervals before a problem is
detected and a ticket is generated.
7
To save your configuration and return to the
Datapath
Conditioning
dialog box, click
OK
.
About the Configuration Record
The configuration record contains details about the library’s
configuration and can be sent to a specified e-mail address or saved as
a.txt file.
Information in the configuration record includes:
• Product information — Product name and version, MCB and RCU
versions, serial number, and modules/drives/partitions
configuration
• License information — License descriptions, quantities, and
installation dates
• Network information — Hostname, DHCP status, IP address, and IP,
Netmask, and Gateway addresses
• Partition information — Serial numbers, online/offline statuses, and
numbers of slots, drives, and I/E slots
• Drive information, for each drive — Location, partition, SCSI
element address, online/offline status, vendor, model, serial number,
logical serial number, firmware version, drive type, and interface
type:
• SCSI tape drives — SCSI ID
• Fibre Channel (FC) tape drives — World Wide Name (WWN) and
loop ID, speed, and connection type
Summary of Contents for Scalar i6000
Page 1: ...User s Guide Scalar i6000 6 66879 15 Rev B...
Page 276: ...Chapter 3 Configuring Your Library Working with Towers 258 Quantum Scalar i6000 User s Guide...
Page 344: ...Chapter 8 Encryption Key Management Using SKM 326 Quantum Scalar i6000 User s Guide...
Page 444: ...Chapter 11 Configuring Access to StorNext 426 Quantum Scalar i6000 User s Guide...
Page 450: ...Chapter 12 Partition Utilization Reporting 432 Quantum Scalar i6000 User s Guide...
Page 574: ...Chapter 15 Maintaining Your Library Maintenance Actions 556 Quantum Scalar i6000 User s Guide...
Page 730: ...Appendix A Frequently Asked Questions 684 Quantum Scalar i6000 User s Guide...