2-51.5
Installation
*: Available for KX-TD1232 only.
8. Open the ROM Cover in the Slave System and set
the Master/Slave switch on the CPU card to “Slave.”
9. Turn the power on.
Notes
• System Connection may take a while (5 to 15 min. depending on your
software version) to be completed after the power is turned on.
Confirm the connection between the systems by making a call from a
Master Unit extension to a Slave Unit extension.
• To turn the power on for the first time, refer to Section 2.6 “Starting the
System for the First Time.”
• The master and slave must have the same version software. Otherwise,
System Connection will not work properly.
• When you install an ISDN S0 Line Unit or/and Card, you should install
it to the Master System first and then the Slave System. If only
installed to the Slave System, noise may occur.
Programming References
Section 4, System Programming,
[115] Adjust Time
Feature References
Section 3, Features,
System Connection
2.4.12 System Connection*
REMOTE
8CO/ISDN
MASTER
SLAVE