4.6
CO Line Programming
Disconnect Time
414
System Programming
4-101
Description
Determines the amount of time between successive accesses to the
same CO line.
Selection
• CO line group (TRG) number: 1 through 8,
(
=all CO line groups)
• Time (seconds): 0.5 / 2.0 / 4.0
Default
All CO line groups – 2.0 s
Programming
1.
Enter 414.
Display: TRG Discnct Time
2.
Press NEXT.
Display : TRK GRP NO?–>
3.
Enter a CO line group number.
To program CO line group number 1, you can also press NEXT.
Display example: TRG1:2.0sec
4.
Keep pressing SELECT until the desired time is displayed.
5.
Press STORE.
6.
To program another CO line group, press NEXT or PREV, or
SELECT and the desired CO line group number.
7.
Repeat steps 4 through 6.
8.
Press END.
Conditions
• The disconnect time must be longer than the requirements of the central
office or the host PBX.
• To assign all CO line groups to one selection, press the
key at step 3.
In this case, the display shows the contents programmed for CO line
group 1.
• Program [401] “CO Line Group Assignment” is used to assign each CO
line to a CO line group.
Feature References
Section 3, Features,
Recall
Summary of Contents for KX-TD1232E
Page 95: ...2 51 8 Blank ...
Page 102: ......
Page 309: ...4 11 2 Blank ...
Page 324: ...4 24 2 Blank ...
Page 352: ...4 42 2 Blank ...
Page 393: ...4 69 14 Blank ...
Page 411: ...4 83 4 Blank ...
Page 492: ...4 142 8 Blank ...
Page 494: ...4 144 Blank ...
Page 532: ......
Page 533: ...Section 5 List This section lists tone ring tone and default values of system programming ...
Page 631: ......