4.2
Manager Programming
TD286 Extension Number Set
017
System Programming
4-35.4
Description
Assigns an extension number to each port which is connected to the
ISDN S0 unit TD286.
Selection
• Port number: KX-TD816 – 01 through 06
KX-TD1232 – 01 through 12
• Extension Number: 1 through 3 digits
Default
All ports – Not Stored
Programming
1.
Enter 017.
Display: TD286 EXT.Number
2.
Press NEXT.
Display example: Port NO?
→
3.
Enter a port number.
To enter port number 01, you can also press NEXT.
Display: #01:Not Stored
4.
Enter an extension number.
To change the current entry, press CLEAR and enter the new number.
5.
Press STORE.
6.
To program another port, press NEXT or PREV, or
SELECT and the desired port number.
7.
Repeat steps 4 through 6.
8.
Press END.
Conditions
• Each extension number can be one through three digits, consisting of 0
through 9. The
and # keys cannot be used.
• A multiple subscriber number (MSN) is determined regarding this
assignment. The MSN consists of the assigned extension number and
an additional digit, 0 through 9.
Example) In case that the ISDN extension number is assigned “3”;
30 through 39 are effective as MSN’s. The extension user can call any
terminal equipment on the ISDN S0 bus with MSN individually.
Pressing “30” calls all extensions on the ISDN S0 bus simultaneously.
• For the KX-TD1232, port number 01 through 06 are for the Master
System and 07 through12 are for the Slave, if available.
Summary of Contents for KX-TD1232E
Page 95: ...2 51 8 Blank ...
Page 102: ......
Page 309: ...4 11 2 Blank ...
Page 324: ...4 24 2 Blank ...
Page 352: ...4 42 2 Blank ...
Page 393: ...4 69 14 Blank ...
Page 411: ...4 83 4 Blank ...
Page 492: ...4 142 8 Blank ...
Page 494: ...4 144 Blank ...
Page 532: ......
Page 533: ...Section 5 List This section lists tone ring tone and default values of system programming ...
Page 631: ......