4.6
CO Line Programming
Pulse Speed Selection
403
System Programming
4-91
Description
A CO line set for pulse or call blocking mode in program [402]
“Dial Mode Selection” can have two pulse rates, 10 pps (low) and
20 pps (high). This program sets the pulse speed for each CO line
set to pulse or call blocking mode.
Selection
• CO line number:
KX-TD816 – 01 through 08,
(
=all CO lines)
KX-TD1232 – 01 through 24,
(
=all CO lines)
• 10 pps / 20 pps
Default
All CO lines – 10 pps
Programming
1.
Enter 403.
Display: Pulse Speed
2.
Press NEXT.
Display: CO Line NO?–>
3.
Enter a CO line number.
To enter CO line number 01, you can also press NEXT.
Display example: CO01:10pps
4.
Keep pressing SELECT until the desired selection is
displayed.
5.
Press STORE.
6.
To program another CO line, press NEXT or PREV, or
SELECT and the desired CO line number.
7.
Repeat steps 4 through 6.
8.
Press END.
Conditions
• In the case of KX-TD1232, CO01 through CO12 are for the Master
System and CO13 through CO24 are for the Slave, if available.
• To assign all CO lines to one selection, press the
key at step 3. In
this case, the display shows the contents programmed for CO01.
• The pulse speed required is determined by the CO or PBX line.
• Program [990] “System Additional Information, Area 02 - Bit 07, 11
and 12” are used to select a pulse break ratio and inter-digit pause, if
needed.
Feature References
Section 3, Features,
Dial Type Selection
Summary of Contents for KX-TD1232E
Page 95: ...2 51 8 Blank ...
Page 102: ......
Page 309: ...4 11 2 Blank ...
Page 324: ...4 24 2 Blank ...
Page 352: ...4 42 2 Blank ...
Page 393: ...4 69 14 Blank ...
Page 411: ...4 83 4 Blank ...
Page 492: ...4 142 8 Blank ...
Page 494: ...4 144 Blank ...
Page 532: ......
Page 533: ...Section 5 List This section lists tone ring tone and default values of system programming ...
Page 631: ......